A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Endovascular Rescue of Sheath Perforation During Inferior Vena Cava Filter Retrieval. | LitMetric

Endovascular Rescue of Sheath Perforation During Inferior Vena Cava Filter Retrieval.

EJVES Vasc Forum

Division of Vascular and Endovascular Surgery, University of Louisville, Louisville, KY, USA.

Published: November 2020

Introduction: Inferior vena cava (IVC) filter retrieval is generally a straightforward procedure but can be challenging with unique complications. A technique used for endovascular rescue of a patient where sheath perforation by the IVC filter occurred during IVC filter retrieval is described.

Report: A 75 year old man underwent retrieval of an IVC filter that had been in place for 10 months. Using the IVC filter retrieval set from a standard right internal jugular vein approach and the loop-snare technique, the hook and collet were captured, and the filter was collapsed into the retrieval sheath. Approximately halfway through removal of the filter through the sheath, mild resistance was encountered and the tip of the IVC filter was found to have perforated the side of the retrieval sheath. The sheath appeared to have bent slightly in this region, probably weakening the sheath wall and creating angulation, which allowed sheath perforation to occur. From a right common femoral vein approach, an Amplatz wire was used to cannulate the distal end of the perforated sheath. A balloon was then used to pull the perforated sheath with the IVC filter into a larger sheath. After removing the Tuohy-Borst and Luer adapters on the perforated sheath, it was able to be internalised and removed via the femoral vein sheath.

Discussion: The endovascular rescue technique described herein may prove useful to other practitioners encountering similar situations, and the complication shows areas of caution when using the loop-snare retrieval technique.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7736903PMC
http://dx.doi.org/10.1016/j.ejvsvf.2020.11.002DOI Listing

Publication Analysis

Top Keywords

ivc filter
28
filter retrieval
16
endovascular rescue
12
sheath
12
sheath perforation
12
perforated sheath
12
filter
10
inferior vena
8
vena cava
8
retrieval
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!