Limited evidence suggests complete arch digital scans are less time efficient than conventional impression.

Evid Based Dent

Professor of Prosthodontics and Member of the Evidence Based Dentistry Centre, Faculty of Dentistry, Cairo University, Egypt.

Published: December 2020

Source of funding This research did not receive any specific grant from funding agencies in the public, commercial, or not-for-profit sectorsType of study/design Randomised controlled trial (RCT) with parallel design.Subjects This RCT was conducted at the Clinic of Fixed and Removable Prosthodontics and Dental Material Science, Centre of Dental Medicine, University of Zurich, Zurich, Switzerland. Ten patients, six women and four men, with a mean age of 62 years and an age range of 49-77 years, requiring posterior tooth-supported 3-unit fixed partial dentures (FPDs) were included in this RCT. The abutment teeth were six molars and six premolars in the maxilla and five molars and three premolars in the mandible. The patients fulfilled the following inclusion criteria: they all were >18 years, with a full mouth plaque score <25% and a full mouth bleeding score <25%. They all needed a posterior tooth-supported FPD, in which the third molar was not an abutment tooth. Only abutments with no extensive pretreatment were eligible. Adjacent and opposing teeth should be healthy or adequately restored.Treatment Three intraoral digital scanning systems (Lava C.O.S.; 3M [Lava], iTero; Align Technology Inc [iTero], Cerec Bluecam; Dentsply Sirona [Cerec]) and conventional light/regular body polyether impression in a stock tray were made on each of the included participants by the same clinician. The opposing arch impression was made in alginate. The sequence of the four techniques was computer generated and concealed in opaque sealed envelopes. Three calibrated experienced clinicians were involved in the treatment. They followed the published guidelines for preparing abutments that receive CAD/CAM ceramic FPDs. After interim prosthesis removal and double retraction cord application, the digital or the conventional impression procedure was started as dictated by the random sequence. Scans were done according to the manufacturer's guidelines, whereby Lava and Cerec required powdering of the teeth by titanium oxide and iTero did not.Main outcome Time needed for obtaining a scan or an impression was calculated. For digital scans it consisted of the time required for powdering, scanning and occlusal registration, while in conventional impression it started from the beginning of impression mixing till tray removal. The number of impression or scan remakes required until results fulfilling the quality criteria were obtained was also recorded. Visual analogue scale (VAS) was used to rate the perception of both, clinicians and patients for the procedures. Patients were asked to rate their comfort with the procedure, while clinicians rated both difficulty and comfort, where 0 indicated uncomfortable and simple and 100 difficult and comfortable. Subjective assessment of the time as judged by the clinicians and the patients was also reported.Main results Generally speaking, conventional impression was better than the three complete arch digital scans, regarding time required in seconds, difficulty for clinicians, comfort and time perception of both patients and clinicians. Number of remakes were highest in iTero (7), followed by Lava, conventional impression and finally Cerec (0). The time required for each technique differed significantly Polyether = 658 (95%CI 528-782) Cerec = 1776 (95%CI 804-2386) iTero = 1107 (785 - 2091). A significant difference was found neither among the three digital impressions, nor between the conventional impression and Lava (μ = 1091, 95%CI [717-1465]). The same findings were reported regarding difficulty for the clinicians. A significant difference was reported between conventional impression (μ = 15, 95%CI [7-24]) and both Cerec (μ = 67, 95%CI [58-77]) and iTero (μ = 43, 95%CI [25-62]). No significant difference was reported among the studied techniques regarding patients' comfort and time perceptions of both clinicians and patients except for a difference in the patients' time perception of Cerec and conventional impression, where P = .035. Regarding the clinicians' comfort a significant difference was only found between conventional impression (μ = 82, 95%CI [69-94]) and Cerec (μ = 32, 95%CI [18-46]).Conclusion Within the limitations of this RCT, it can be concluded that complete arch conventional impression is objectively less time consuming and subjectively preferred by both clinicians and patients when compared to digital scanning. Digital scanning techniques, requiring powdering, are more difficult for the clinicians than powderless ones and conventional impression.

Download full-text PDF

Source
http://dx.doi.org/10.1038/s41432-020-0143-1DOI Listing

Publication Analysis

Top Keywords

limited evidence
4
evidence suggests
4
suggests complete
4
complete arch
4
arch digital
4
digital scans
4
scans time
4
time efficient
4
efficient conventional
4
conventional impression
4

Similar Publications

Voice Quality as Digital Biomarker in Bipolar Disorder: A Systematic Review.

J Voice

January 2025

Department of Surgery, UMONS Research Institute for Health Sciences and Technology, University of Mons (UMons), Mons, Belgium; Division of Laryngology and Bronchoesophagology, Department of Otolaryngology Head Neck Surgery, EpiCURA Hospital, Baudour, Belgium; Department of Otolaryngology-Head and Neck Surgery, Foch Hospital, School of Medicine, UFR Simone Veil, Université Versailles Saint-Quentin-en-Yvelines (Paris Saclay University), Paris, France; Department of Otolaryngology, Elsan Hospital, Paris, France. Electronic address:

Background: Voice analysis has emerged as a potential biomarker for mood state detection and monitoring in bipolar disorder (BD). The systematic review aimed to summarize the evidence for voice analysis applications in BD, examining (1) the predictive validity of voice quality outcomes for mood state detection, and (2) the correlation between voice parameters and clinical symptom scales.

Methods: A PubMed, Scopus, and Cochrane Library search was carried out by two investigators for publications investigating voice quality in BD according to Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statements.

View Article and Find Full Text PDF

Social isolation as a determinant of mental health among hybrid employees in the United States.

J Affect Disord

January 2025

Center for Anti-racism, Social Justice & Public Health, New York University School of Global Public Health, New York, NY, USA; Department of Biostatistics, New York University School of Global Public Health, New York, NY, USA. Electronic address:

Background: A knowledge gap exists in understanding the role of social isolation as a determinant of mental health among hybrid employees during the COVID-19 era.

Methods: Using 2024 Household Pulse Survey data, we investigated the relationship between social isolation and mental health among US hybrid employees. We assessed depression symptoms using the Patient Health Questionnaire-2 and anxiety symptoms using the Generalized Anxiety Disorder-2.

View Article and Find Full Text PDF

Cardiotoxicity of polystyrene nanoplastics and associated mechanism of myocardial cell injury in mice.

Ecotoxicol Environ Saf

January 2025

Department of Cardiology, The Second Affiliated Hospital, Jiangxi Medical College, Nanchang University, No. 1 Minde Road, Nanchang, Jiangxi Province 330006, China. Electronic address:

Aims: Nanoplastics (NPs) are emerging organic pollutants generated by plastic degradation and are ubiquitous in the environment. They can be accumulated through the food webs and enter the human body through dietary intake, posing health risks. The main target organs of NP accumulation are the lungs, liver, heart, and kidneys.

View Article and Find Full Text PDF

Subsets of extraocular motoneurons produce kinematically distinct saccades during hunting and exploration.

Curr Biol

January 2025

Department of Neuroscience, Physiology & Pharmacology, UCL, Gower Street, London WC1E 6BT, UK. Electronic address:

Animals construct diverse behavioral repertoires by moving a limited number of body parts with varied kinematics and patterns of coordination. There is evidence that distinct movements can be generated by changes in activity dynamics within a common pool of motoneurons or by selectively engaging specific subsets of motoneurons in a task-dependent manner. However, in most cases, we have an incomplete understanding of the patterns of motoneuron activity that generate distinct actions and of how upstream premotor circuits select and assemble such motor programs.

View Article and Find Full Text PDF

The (in)dependence of single-cell data inferences on model constructs.

Forensic Sci Int Genet

January 2025

Center for Computational and Integrative Biology, Rutgers University, Camden, NJ 08102, USA; Department of Computer Science,  Rutgers University, Camden, NJ 08102, USA.

Recent developments in single-cell analysis have revolutionized basic research and have garnered the attention of the forensic domain. Though single-cell analysis is not new to forensics, the ways in which these data can be generated and interpreted are. Modern interpretation strategies report likelihood ratios that rely on a model of the world that is a simplification of it.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!