In this study, a high-density polyethylene (HDPE)-based carbon fiber-reinforced thermoplastic (CFRTP) was irradiated by an electron-beam. To assess the absorbed dose rate influence on its mechanical properties, the beam energy and absorbed dose were fixed, while the absorbed dose rates were varied. The tensile strength (TS) and Young's modulus (YM) were evaluated. The irradiated CFRTP TS increased at absorbed dose rates of up to 6.8 kGy/s and decreased at higher rates. YM showed no meaningful differences. For CFRTPs constituents, the carbon fiber (CF) TS gradually increased, while the HDPE TS decreased slightly as the absorbed dose rates increased. The OH intermolecular bond was strongly developed in irradiated CFRTP at low absorbed dose rates and gradually declined when increasing those rates. X-ray photoelectron spectroscopy analysis revealed that the oxygen content of irradiated CFRTPs decreased with increasing absorbed dose rate due to the shorter irradiation time at higher dose rates. In conclusion, from the TS viewpoint, opposite effects occurred when increasing the absorbed dose rate: a favorable increase in CF TS and adverse decline of attractive hydrogen bonding interactions between HDPE and CF for CFRTPs TS. Therefore, the irradiated CFRTP TS was maximized at an optimum absorbed dose rate of 6.8 kGy/s.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7765887PMC
http://dx.doi.org/10.3390/polym12123012DOI Listing

Publication Analysis

Top Keywords

absorbed dose
40
dose rate
20
dose rates
20
irradiated cfrtp
12
dose
11
absorbed
9
mechanical properties
8
carbon fiber
8
irradiated electron-beam
8
increasing absorbed
8

Similar Publications

Purpose: Long axial field-of-view (LAFOV) positron emission tomography/computed tomography (PET/CT) scanners enable high sensitivity and wide anatomical coverage. Therefore, they seem ideal to perform post-selective internal radiation therapy (SIRT) Y scans, which are needed, to confirm that the dose is delivered to the tumors and that healthy organs are spared. However, it is unclear to what extent the use of LAFOV PET is feasible and which dosimetry approaches results in accurate measurements.

View Article and Find Full Text PDF

Background: Huntington's disease (HD) is a rare neurodegenerative disorder caused by an expansion of the CAG trinucleotide repeat in the huntingtin gene which encodes the mutant huntingtin protein (mHTT) that is associated with HD-related neuropathophysiology. Noninvasive visualization of mHTT aggregates in the brain, with positron emission tomography (PET), will allow to reliably evaluate the efficacy of therapeutic interventions in HD. This study aimed to assess the radiation burden of [F]CHDI-650, a novel fluorinated mHTT radioligand, in humans based on both in vivo and ex vivo biodistribution in mice and subsequent determination of dosimetry for dosing in humans.

View Article and Find Full Text PDF

PATHOGENESIS OF RADIATION COMPLICATIONS IN NORMAL TISSUES SURROUNDING AN IRRADIATED TUMOUR (review).

Probl Radiac Med Radiobiol

December 2024

R.E. Kavetsky Institute of Experimental Pathology, Oncology and Radiobiology, National Academy of Sciences of Ukraine, 45 Vasylkivska Str., Kyiv, 03022, Ukraine.

The introduction of new radiation technologies in modern radiotherapy of cancer patients is still in some cases associated with the risk of developing early and distant complications in healthy tissues surrounding the tumour. The causes of their occurrence, pathogenesis and radiobiological characteristics are reviewed and briefly described. The rate of the manifestation of complications depends on the radiosensitivity of tissues and is determined by the amount of absorbed dose of ionizing radiation.

View Article and Find Full Text PDF

Background: Elinzanetant is a dual neurokinin-1,3 receptor antagonist in development for the treatment of menopausal vasomotor symptoms. The objectives of these studies were to characterize the mass balance and biotransformation of elinzanetant.

Methods: In the clinical evaluation, whole blood, plasma, urine, and feces were collected from healthy fasted male volunteers (n = 6) following a single dose of 120 mg [C]-elinzanetant oral suspension for analysis of total radioactivity and metabolite profiling.

View Article and Find Full Text PDF

Identification, annotation and toxicity estimation of organic pollutants in human serum via non-target analysis.

Environ Pollut

December 2024

State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, Nanjing, 210023, People's Republic of China.

Environmental organic pollution causes a threat to the ecological environment, constrains social development and can also potentially harm human health. We applied non-target analysis to screen organic pollutants from the serum of 89 individuals, identifying 67 pollutants in the categories of industrial intermediates, plasticizers, surfactants, pharmaceuticals, pesticides, and exogenous pollutant metabolites. The detection rate of chemicals for industrial use (50.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!