Background: The aim is to demonstrate the validity of the monitoring through intraoral scanner of the dental movements and the real impact, advantages, and convenience, in terms of treatment time and efficiency gain, to frequently monitor a patient with the scanner application.

Methods: A movement control of palatally impacted canines was performed, surgically treated with laser opercolectomy. Three-dimensional models of the patient's dental arch were obtained with intraoral scanner during a monitoring time of 4 months. The STL (Standard Triangle Language) files were superimposed with the 3D models extrapolated from the pre-operative CT (Computerized Tomography). The measurements of eruption, exposed palatal and vestibular areas, and distances between the canines and the incisors were performed, using digital technologies and with a digital caliber.

Results: Descriptive and inferential statistical analysis of the data obtained from both conventional and digital monitoring has been realized and performing the T Student Test for paired data.

Conclusion: The advantages of digital monitoring are numerous, like the possibility to reduce the error of method caused by manual measurement on plaster casts and the possibility to compare the pattern and amount of eruption of the canine in the same patient overtime.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7765620PMC
http://dx.doi.org/10.3390/ijerph17249428DOI Listing

Publication Analysis

Top Keywords

intraoral scanner
8
digital monitoring
8
cbct intra-oral
4
scanner
4
intra-oral scanner
4
scanner advantages
4
advantages technologies
4
technologies orthodontic
4
orthodontic treatment
4
treatment background
4

Similar Publications

The technical development of implant-supported fixed dental prostheses (iFDP) initially concentrated on the computer-aided manufacturing of prosthetic restorations (CAM). Advances in information technologies have shifted the focus for optimizing digital workflows to AI-based processes for design (CAD). This pre-clinical pilot trial investigated the feasibility of the automatic design of three-unit iFDPs using CAD software (Dental Manger 2021, 3Shape; DentalCAD 3.

View Article and Find Full Text PDF

The aim of this study was to systematically revise the state of art of the accuracy of digital and conventional impressions in clinical full-arch scenarios. Electronic and manual searches were conducted up to December 2024. Only trials comparing the accuracy of digital versus conventional impressions were selected by two independent reviewers.

View Article and Find Full Text PDF

Objective: To assess the reproducibility and reliability of the pink (PES) and white esthetic scores (WES) using digital images and the intra- and inter-examiner agreement among different clinical backgrounds and assessment methods.

Material And Methods: Standardized intraoral images were obtained from adult subjects with an implant-supported single-tooth fixed dental prosthesis located in the maxillary esthetic zone using a digital camera and a true-color intraoral scanner. According to the PES and WES criteria, the images were evaluated by 20 calibrated evaluators, 5 prosthodontists, 5 periodontists, 5 undergraduates, and 5 oral surgeons.

View Article and Find Full Text PDF

Introduction: This study aimed to evaluate the stability of palatal rugae patterns after slow maxillary expansion (SME) treatment and the reliability of the rugae region as a reference region in digital superimposition.

Methods: The SME group comprised 21 subjects with Angle Class I or Class II dental malocclusion with unilateral or bilateral crossbite and constricted maxilla and were selected before the pubertal peak. Intraoral scans were captured via the intraoral scanner iTero Element software (version 1.

View Article and Find Full Text PDF

Dentistry is steadily evolving along the digital pathway at a constant and sure pace. Intraoral scanners (IOSs) started to enhance the precision and trueness of the restorations, making prosthodontics treatment more predictable. The objective of this study was to compare the trueness and internal fit of the printed provisional veneers for 60 preparations with three different types of finish lines.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!