A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Potential benefits of adaptive intensity-modulated proton therapy in nasopharyngeal carcinomas. | LitMetric

Purpose: To investigate potential advantages of adaptive intensity-modulated proton beam therapy (A-IMPT) by comparing it to adaptive intensity-modulated X-ray therapy (A-IMXT) for nasopharyngeal carcinomas (NPC).

Methods: Ten patients with NPC treated with A-IMXT (step and shoot approach) and concomitant chemotherapy between 2014 and 2016 were selected. In the actual treatment, 46 Gy in 23 fractions (46Gy/23Fx.) was prescribed using the initial plan and 24Gy/12Fx was prescribed using an adapted plan thereafter. New treatment planning of A-IMPT was made for the same patients using equivalent dose fractionation schedule and dose constraints. The dose volume statistics based on deformable images and dose accumulation was used in the comparison of A-IMXT with A-IMPT.

Results: The means of the D of the right parotid gland (P < 0.001), right TM joint (P < 0.001), left TM joint (P < 0.001), oral cavity (P < 0.001), supraglottic larynx (P = 0.001), glottic larynx (P < 0.001), , middle PCM (P = 0.0371), interior PCM (P < 0.001), cricopharyngeal muscle (P = 0.03643), and thyroid gland (P = 0.00216), in A-IMPT are lower than those of A-IMXT, with statistical significance. The means of, D , and D of each sub portion of auditory apparatus and D for Eustachian tube and D for mastoid volume in A-IMPT are significantly lower than those of A-IMXT. The mean doses to the oral cavity, supraglottic larynx, and glottic larynx were all reduced by more than 20 Gy (RBE = 1.1).

Conclusions: An adaptive approach is suggested to enhance the potential benefit of IMPT compared to IMXT to reduce adverse effects for patients with NPC.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7856494PMC
http://dx.doi.org/10.1002/acm2.13128DOI Listing

Publication Analysis

Top Keywords

adaptive intensity-modulated
12
intensity-modulated proton
8
nasopharyngeal carcinomas
8
potential benefits
4
benefits adaptive
4
proton therapy
4
therapy nasopharyngeal
4
carcinomas purpose
4
purpose investigate
4
investigate potential
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!