Enhancing sensitivity of microbial fuel cell sensors for low concentration biodegradable organic matter detection: Regulation of substrate concentration, anode area and external resistance.

J Environ Sci (China)

Key Laboratory of Reservoir Aquatic Environment, Chinese Academy of Sciences, Chongqing 400714, China; Chongqing Institute of Green and Intelligent Technology, Chinese Academy of Sciences, Chongqing 400714, China; University of Chinese Academy of Sciences, Beijing100049, China.

Published: March 2021

AI Article Synopsis

  • The low sensitivity of microbial fuel cell (MFC) sensors limits their application in detecting low concentrations of biodegradable organic matter (BOM).
  • Optimizing startup parameters, such as substrate concentration and anode area, as well as using an external resistance of 210 Ω, significantly improves sensor sensitivity.
  • The enhanced sensitivity leads to a lower detection limit (1 mg/L) and higher coulombic efficiency, facilitating more effective detection of low concentration BOM.

Article Abstract

The relatively low sensitivity is an important reason for restricting the microbial fuel cell (MFC) sensors' application in low concentration biodegradable organic matter (BOM) detection. The startup parameters, including substrate concentration, anode area and external resistance, were regulated to enhance the sensitivity of MFC sensors. The results demonstrated that both the substrate concentration and anode area were positively correlated with the sensitivity of MFC sensors, and an external resistance of 210 Ω was found to be optimal in terms of sensitivity of MFC sensors. Optimized MFC sensors had lower detection limit (1 mg/L) and higher sensitivity (Slope value of the linear regression curve was 1.02), which effectively overcome the limitation of low concentration BOM detection. The essential reason is that optimized MFC sensors had higher coulombic efficiency, which was beneficial to improve the sensitivity of MFC sensors. The main impact of the substrate concentration and anode area was to regulate the proportion between electrogens and nonelectrogens, biomass and living cells of the anode biofilm. The external resistance mainly affected the morphology structure and the proportion of living cells of the anode. This study demonstrated an effective way to improve the sensitivity of MFC sensors for low concentration BOM detection.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jes.2020.08.020DOI Listing

Publication Analysis

Top Keywords

mfc sensors
28
sensitivity mfc
20
low concentration
16
substrate concentration
16
concentration anode
16
anode area
16
external resistance
16
bom detection
12
microbial fuel
8
fuel cell
8

Similar Publications

Microfibrillated cellulose (MFC), a sustainable material derived from biomass, stands out as an environmentally friendly alternative for developing chemical sensors owing to its advantageous properties, including high porosity, surface area, and available surface functional groups. Herein, we propose a simple and low-cost strategy for developing cellulose-based strips for the colorimetric detection of total iron in water. The strips were prepared by functionalizing MFC casting membranes with 1-(2-Thiazolylazo)-2-naphthol (TAN), which was then characterized by structural and morphological techniques.

View Article and Find Full Text PDF

Piezoelectric materials are increasingly used in portable smart electronics and Internet of Things sensors. Among them, piezoelectric macro fiber composites (MFCs) have attracted much attention due to their architectural simplicity, scalability, and high-power density. However, most MFCs currently use toxic lead-based piezoelectric materials, hindering their applications for bio-friendly intelligent electronics.

View Article and Find Full Text PDF

We introduce a groundbreaking proof-of-concept for a novel glucose monitoring transducing mechanism, marking the first demonstration of a spore-forming microbial whole-cell sensing platform. The approach uses selective and sensitive germination of Bacillus subtilis spores in response to glucose in potassium-rich bodily fluids such as sweat. As the rate of germination and the number of metabolically active germinating cells are directly proportional to glucose concentration, the electrogenic activity of these cells-manifested as electricity-serves as a self-powered transducing signal for glucose detection.

View Article and Find Full Text PDF

Mechanochromic Organic Micro-Laser.

Angew Chem Int Ed Engl

November 2024

State Key Laboratory of Applied Organic Chemistry (SKLAOC), Key Laboratory of Special Function Materials and Structure Design (MOE), College of Chemistry and Chemical Engineering, Lanzhou University, Lanzhou, 730000, P. R. China.

This work presents the first demonstration of a mechanochromic organic micro-laser, which exhibits remarkable wide range pressure sensing characteristics. The gain material, pinacolato boronate ester functionalized anthanthrene (AnBPin), is designed by incorporating mechanofluorochromic (MFC) properties into organic laser dye. The AnBPin exhibits a reversible transition between green and orange fluorescence upon grinding annealing and recrystallization cycle, and its micro-crystal exhibits typical organic micro-laser behaviors.

View Article and Find Full Text PDF

Microbial fuel cells (MFCs) represent a promising technology for sustainable energy generation, which leverages the metabolic activities of microorganisms to convert organic substrates into electrical energy. In oil spill scenarios, hydrocarbonoclastic biofilms naturally form at the water-oil interface, creating a distinct environment for microbial activity. In this work, we engineered a novel MFC that harnesses these biofilms by strategically positioning the positive electrode at this critical junction, integrating the biofilm's natural properties into the MFC design.

View Article and Find Full Text PDF