Purpose: The intranasal (IN) administration of radiopharmaceuticals is of interest in being a viable route for the delivery of radiopharmaceuticals that do not ordinarily cross the blood-brain barrier (BBB). However, to be viable in a patient population, good image quality as well as safety of the administration should be demonstrated. This work provides radiation dosimetry calculations and simulations related to the radiation safety of performing such experiments in a human cohort.

Methods: We performed Monte Carlo (MC) simulations to estimate radiation dose to the skin inside a cylindrical model of the nasal cavity assuming a homogenous distribution layer of C and F and calculated a geometry conversion factor (F ) which can be used to convert from a planar geometry to a cylindrical geometry using more widely available software tools. We compared radiation doses from our simulated cylindrical geometry with the planar dose estimates employing our geometry conversion factor from VARSKIN 6.1 software and also from an analytical equation. Furthermore, in order to estimate radiation dosimetry to surrounding organs of interest, we performed a voxelized MC simulation of a fixed radioactivity inside the nasal cavity and calculated S-values to organs such as the eyes, thyroid, and brain.

Results: MC simulations of contamination scenarios using planar absorbed doses of 15.50 and 8.60 mGy/MBq for F and C, respectively, and 35.70 and 19.80 mGy/MBq per hour for cylindrical geometries, leading to determination of an F of 2.3. Planar absorbed doses (also in units of mGy/MBq) determined by the analytical equation were 16.96 and 8.68 ( F and C) and using VARSKIN were 16.60 and 9.26 ( F and C), respectively. Application of F to these results demonstrates values with a maximum difference of 9.41% from the cylindrical geometry MC calculation, demonstrating that when accounting for geometry, more simplistic techniques can be utilized to estimate IN dosimetry. Voxelized MC simulations of radiation dosimetry from a fixed source of 1 MBq of activity confined to the nasal cavity resulted in S-values to the thyroid, eyes, and brain of 1.72 x 10 , 1.93 x 10 , and 3.51 x 10  mGy/MBq·s, respectively, for F and 1.80 × 10 , 1.95 × 10 , and 3.54 × 10  mGy/MBq·s for C.

Conclusion: Dosimetry concerns about IN administrations of PET radiotracers should be considered before clinical use. Values presented in the simulations such as the S-values can be further used for assessment of absorbed doses in cases of IN administration, and can be used to develop and adapt specific study protocols. All three presented methods provided similar results when considering the use of a geometry conversion factor for planar to cylindrical geometry, demonstrating that standard tools rather than dedicate MC simulations may be used to perform dose calculations in nasal administrations.

Download full-text PDF

Source
http://dx.doi.org/10.1002/mp.14669DOI Listing

Publication Analysis

Top Keywords

cylindrical geometry
16
radiation dosimetry
12
nasal cavity
12
geometry conversion
12
conversion factor
12
absorbed doses
12
geometry
9
radiation doses
8
s-values organs
8
monte carlo
8

Similar Publications

This study emphasizes the importance of optimizing pin-finned heat sinks as a means of addressing thermal engineering issues. It aims to investigate the use of perforations and unique fin designs in relation to staggered pin arrays in order to fill a gap in existing research. Three-dimensional incompressible flow simulation is performed with the Fluent software.

View Article and Find Full Text PDF

Most NMR samples are cylindrical, which is ideal for obtaining high-resolution NMR spectra, especially in superconducting magnets with a vertical bore. However, expanding NMR applicability to samples that are not necessarily cylindrical requires a new approach. In this study, we introduce a method for obtaining solution NMR signals from flat samples, such as flat containers or layered structures like a fuel cell.

View Article and Find Full Text PDF

The formation of a functional tibial stump after combat injuries with extensive tissue damage is sometimes difficult. We describe a case of reconstruction of the tibial stump after a mine-blast injury. In this case, the fibula was completely removed as a result of fracture, and the tibia was amputated at the border of the upper and middle thirds.

View Article and Find Full Text PDF

This study introduces a novel analytical framework for investigating the vibration characteristics of functionally graded carbon nanotube-reinforced composite (FG-CNTRC) elliptical cylindrical shells under arbitrary boundary conditions. Unlike previous studies that focused on simplified geometries or specific boundary conditions, this work combines the least-squares weighted residual method (LSWRM) with an adapted variational principle, addressing high-order vibration errors and ensuring continuity across structural segments. The material properties are modeled using an extended rule of mixtures, capturing the effects of carbon nanotube volume fractions and distribution types on structural dynamics.

View Article and Find Full Text PDF

Numerical Investigation of a Microfluidic Biosensor Based on I-Shaped Micropillar Array Electrodes.

Sensors (Basel)

December 2024

Department of Electrical and Computer Engineering, Bucknell University, Lewisburg, PA 17837, USA.

Micropillar array electrodes offer several advantages, such as enhanced mass transport, lower detection limits, and the potential for miniaturization, making them instrumental in the design and fabrication of electrochemical biosensors. The performance of these biosensors is influenced by electrode geometry, including parameters like shape and height, which affect surface area and overall sensitivity. In this study, we designed a microfluidic electrochemical biosensor featuring micropillar array electrodes, modeled in COMSOL Multiphysics.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!