Objective: To investigate the value of a notched unipolar electrogram (N-uniEGM) in confirming the origin of premature ventricular contractions originating from the ventricular outflow tract (VOT-PVC) during mapping and ablation procedures.

Methods: This retrospective study enrolled consecutive patients with symptomatic idiopathic frequent VOT-PVCs that underwent radiofrequency ablation. The characteristics of the uniEGM of the successful ablation targets were analysed. N-uniEGM was defined as the uniEGM presenting a QS morphology with ≥1 steep notches on the downstroke deflection. All patients were followed-up for 3 months post-ablation.

Results: The study enrolled 190 patients with a mean ± SD age of 49.0 ± 15.3 years. N-uniEGMs were recorded in 124 of 190 (65.3%) patients. The N-uniEGM distribution area was limited to a mean ± SD of 0.8 ± 0.4 cm. N-uniEGM showed consistency with the outcomes of activation mapping and pace mapping. Patients with an N-uniEGM had an ablation success rate of 98.4% (122 of 124) and their ablation times were significantly shorter than those without an N-uniEGM (7.6 ± 3.8 s versus 15.8 ± 8.8 s, respectively). The sensitivity and specificity of N-uniEGM in predicting successful ablation of VOT-PVCs were 72.6% and 91.7%, respectively.

Conclusion: N-uniEGM was a highly specific and moderately sensitive predictor of successful radiofrequency ablation in patients with VOT-PVCs.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7747111PMC
http://dx.doi.org/10.1177/0300060520977634DOI Listing

Publication Analysis

Top Keywords

notched unipolar
8
unipolar electrogram
8
ablation
8
premature ventricular
8
ventricular contractions
8
contractions originating
8
originating ventricular
8
ventricular outflow
8
outflow tract
8
n-uniegm
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!