Photoacoustic spectroscopy (PAS) is a sensitive technique for the detection of trace gases and aerosols and measurements of their absorption coefficients. The accuracy of such measurements is often governed by the fidelity of the PAS instrument calibration. Gas samples laden with O3 of a known or independently measured absorption coefficient are a convenient and commonplace route to calibration of PAS instruments operating at visible wavelengths (λ), yet the accuracy of such calibrations remains unclear. Importantly, the photoacoustic detection of O3 in the Chappuis band (λ ∼ 400-700 nm) depends strongly on the timescales for energy transfer from the nascent photoproducts O(3P) and O2(X, v > 0) to translational motion of bath gas species. Significant uncertainties remain concerning the dependence of these timescales on both the sample pressure and the bath gas composition. Here, we demonstrate accurate characterisation of microphone response function dependencies on pressure using a speaker transducer to excite resonant acoustic modes of our photoacoustic cells. These corrections enable measurements of photoacoustic response amplitudes (also referred to as PAS sensitivities) and phase shifts with variation in static pressure and bath gas composition, at discrete visible wavelengths spanning the Chappuis band. We develop and fit a photochemical relaxation model to these measurements to retrieve the associated variations in the aforementioned relaxation timescales for O(3P) and O2(X, v > 0). These timescales enable a full assessment of the accuracy of PAS calibrations using O3-laden gas samples, dependent on the sample pressure, bath gas composition and PAS laser modulation frequency.

Download full-text PDF

Source
http://dx.doi.org/10.1039/d0cp05056cDOI Listing

Publication Analysis

Top Keywords

bath gas
16
chappuis band
12
pressure bath
12
gas composition
12
energy transfer
8
gas samples
8
visible wavelengths
8
o3p o2x
8
sample pressure
8
pas
6

Similar Publications

SLowFlowS: A novel flow standard for semiconductor process gases.

Flow Meas Instrum

March 2025

Fluid Metrology Group, Sensor Science Division, National Institute of Standards and Technology, Gaithersburg, MD 20899.

Numerous process gases are used in the production of semiconductor chips. Accurate metering of these gases into process chambers is critical for maximizing device throughput and yield. A national flow standard for semiconductor process gases does not exist, forcing the industry to rely on approximate "meter factors" to extrapolate a meter calibration carried out with nitrogen to the actual process gas.

View Article and Find Full Text PDF

Quantum mechanical vibrational coherence transfer processes play important roles in energy relaxation, charge transfer, and reaction dynamics in chemical and biological systems but are difficult to directly measure using traditional condensed-phase nonlinear spectroscopies. Recently, we developed a new experimental capability to obtain two-dimensional infrared (2D IR) spectra of molecular systems in the gas phase that enables the direct measurement of coherence pathways. Herein, we report ultrafast 2D IR spectroscopy of the peptide glutathione (GSH) isolated and cryogenically cooled in the gas phase.

View Article and Find Full Text PDF

Introduction: We reviewed a 7-year experience (Jan 2016 to Oct 2023) in diagnosing and surgically treating Acquired Rectovestibular Fistula (ARVF). Our study describes the medical history, introduces new classifications based on fistula features, and outlines the application of diverse surgical techniques in treating these patients.

Methods: A total of 78 girls with ARVF appeared asymptomatic at birth.

View Article and Find Full Text PDF

Background: Hygiene and skin care are crucial for stroke patients in intensive care, yet the effects of bathing practices on vital signs in mechanically ventilated stroke patients remain underexplored.

Aim: This study aimed to assess the effects of full bed baths and wiping baths on vital signs in stroke patients.

Study Design: A self-comparison pre-experimental study was conducted with 90 stroke patients treated in three intensive care units at a Turkish hospital between 10 January 2021 and 01 January 2022.

View Article and Find Full Text PDF

Estimation of public exposure to PAH and environmental risks via wastewater-based epidemiology.

Ecotoxicol Environ Saf

February 2025

University of Bath, Department of Chemistry, Bath BA2 7AY, UK; Centre of Excellence in Water-Based Early Warning Systems for Health Protection, University of Bath, Bath BA25RX, UK. Electronic address:

The wastewater-based epidemiology (WBE) has the potential to monitor public health emergencies via the analysis of human urinary biomarkers in wastewater. This work proposes a novel approach utilizing WBE for the spatial and temporal evaluation of PAHs exposure using hydroxyl derivatives of PAHs. These are 1-hydroxynaphthalene, 2-hydroxynaphthalene, 2-hydroxyfluorene, 9-hydroxyfluorene, 9-hydroxyphenanthrene, 1-hydroxypyrene and 3-hydroxybenzo(a)pyrene.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!