Before the advent of modern tomographic imaging and corneal cross-linking (CXL), diagnosis and treatment of ectatic disease were limited to disease severity where changes on the anterior corneal surface lead to visual complaints. Rigid contact lenses and/or penetrating keratoplasty addressed late stage disease, as identifying early or subclinical disease was not possible, or its need appreciated. The emergence of CXL as a viable treatment to alter the natural progression of keratoconus heightened the need for improved diagnostics.Several methods have been described in the literature to evaluate and document progression in keratoconus, but there has been no consistent definition of ectasia progression. Newer imaging techniques (ie, tomography) allowed the detection of earlier ectatic disease, before visual loss and subjective complaints. The Belin ABCD classification/staging system was introduced on a Scheimpflug imaging system [Pentacam, (Oculus GmbH, Wetzlar, Germany)] to address previous shortcomings. The ABCD system utilizes 4 parameters: Anterior ("A") and posterior ("B" for Back) radius of curvature taken from a 3.0 mm optical zone centered on the thinnest point, "C" is minimal Corneal thickness, and "D" best spectacle Distance visual acuity. The first 3 parameters (A, B, C) are machine-generated objective measurements that can be used to determine progressive change.The staging system is not limited to a specific commercial entity and can be incorporated in any tomographic imaging system. The ABCD Progression Display graphically displays each parameter and shows when statistical change above measurement noise is reached. This should allow the clinician the ability to diagnose progressive disease at a much earlier stage than was previously possible, with the confidence that earlier intervention could prevent visual loss.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/APO.0000000000000333 | DOI Listing |
Circ Cardiovasc Interv
January 2025
Division of Cardiology, Department of Medicine, University of Washington Medical Center, Seattle (E.J.S., T. Salahuddin, J.A.D.).
Background: Intravascular imaging (IVI) is widely recognized to improve outcomes after percutaneous coronary intervention (PCI). However, IVI is underutilized and is not yet established as a performance measure for quality PCI.
Methods: We examined temporal trends of IVI use for all PCIs performed at Veterans Affairs hospitals in the United States from 2010 to 2022 using retrospective observational cohorts.
Circ Cardiovasc Interv
January 2025
Centre for Cardiovascular Innovation, University of British Columbia, Vancouver, Canada. (A.H., J.J., S.O., K.M., J.A.L., P.B., D.A.W., S.L.S., J.G.W., J.S.).
Background: Transcatheter heart valve (THV) underexpansion after transcatheter aortic valve replacement may be associated with worse outcomes. THV expansion can be assessed fluoroscopically using a pigtail for calibration; however, the accuracy of this technique specific to transcatheter aortic valve replacement is unknown. We assessed the accuracy and reproducibility of a novel fluoroscopic method to assess THV expansion using the THV commissural post for calibration.
View Article and Find Full Text PDFStroke
January 2025
Department of Neurology, University of Pennsylvania, PA. (L.I., S.E.Z., S.E.K., B.L.C.).
Background: A modified computed tomography angiography (CTA)-based Carotid Plaque Reporting and Data System (Plaque-RADS) classification was applied to a cohort of patients with embolic stroke of undetermined source to test whether high-risk Plaque-RADS subtypes are more prevalent on the ipsilateral side of stroke. With the widespread use of CTA for stroke evaluation, a CTA-based Plaque-RADS would be valuable for generalizability.
Methods: A retrospective observational cross-sectional study was conducted at a single integrated health system comprised of 3 hospitals with a comprehensive stroke center between October 1, 2015, and April 1, 2017.
Several studies suggested that total hip arthroplasty (THA) was more technical demanding following previous pelvic osteotomy (PO), resulting in poor outcomes compared with primary THA. However, the other studies regarding this topic had reported contradictory results. Therefore, we conducted this meta-analysis to compare the clinical results and other parameters between total hip arthroplasty following pelvic osteotomy and primary total hip arthroplasty.
View Article and Find Full Text PDFDespite an increasing number of studies examining the effect of Single-Photon Emission Computed Tomography/ Computed Tomography (SPECT/CT) on improvement of diagnosis of aseptic loosening, there is still a great deal of uncertainty regarding its applicability in diagnostic algorithm. Therefore, in this meta-analysis, we aimed to investigate the diagnostic performance of SPECT/CT for identification of aseptic loosening in patients with persistent pain following the total knee arthroplasty (TKA) and total hip arthroplasty (THA). Electronic databases including Medline, Scopus, Web of Science, Cochrane library, and Embase were systematically searched for identifying relevant published studies from their inception to April 2023.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!