Despite promising results obtained in the early diagnosis of several pathologies, breath analysis still remains an unused technique in clinical practice due to the lack of breath sampling standardized procedures able to guarantee a good repeatability and comparability of results. The most diffuse on an international scale breath sampling method uses polymeric bags, but, recently, devices named Mistral and ReCIVA, able to directly concentrate volatile organic compounds (VOCs) onto sorbent tubes, have been developed and launched on the market. In order to explore performances of these new automatic devices with respect to sampling in the polymeric bag and to study the differences in VOCs profile when whole or alveolar breath is collected and when pulmonary wash out with clean air is done, a tailored experimental design was developed. Three different breath sampling approaches were compared: (a) whole breath sampling by means of Tedlar bags, (b) the end-tidal breath collection using the Mistral sampler, and (c) the simultaneous collection of the whole and alveolar breath by using the ReCIVA. The obtained results showed that alveolar fraction of breath was relatively less affected by ambient air (AA) contaminants (-values equal to 0.04 for Mistral and 0.002 for ReCIVA Low) with respect to whole breath (-values equal to 0.97 for ReCIVA Whole). Compared to Tedlar bags, coherent results were obtained by using Mistral while lower VOCs levels were detected for samples (both breath and AA) collected by ReCIVA, likely due to uncorrected and fluctuating flow rates applied by this device. Finally, the analysis of all data also including data obtained by explorative analysis of the unique lung cancer (LC) breath sample showed that a clean air supply might determine a further confounding factor in breath analysis considering that lung wash-out is species-dependent.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7763204 | PMC |
http://dx.doi.org/10.3390/molecules25245823 | DOI Listing |
Neurogastroenterol Motil
January 2025
Division of Gastroenterology and Hepatology, Mayo Clinic, Rochester, Minnesota, USA.
Background: The carbon-13 spirulina gastric emptying breath test (GEBT) is approved to identify delayed, but not accelerated, gastric emptying (GE). We compared the utility of the GEBT to scintigraphy for diagnosing abnormal GE in patients with diabetes mellitus.
Methods: Twenty-eight patients with diabetes ate a 230-kcal test meal labeled with technetium 99 m and C-spirulina, after which 10 scintigraphic images and breath samples (baseline, 15, 30, 45, 60, 90, 120, 150, 180, 210, and 240 min) were collected on 2 occasions 1 week apart.
Front Med (Lausanne)
January 2025
Xuanwu Hospital, Capital Medical University, Beijing, China.
Purpose: To study the effects of breathing exercises on preventing pulmonary complications in patients undergoing coronary artery bypass graft surgery.
Methods: Observing whether preoperative breathing exercises can reduce the incidence of postoperative pulmonary complications in patients undergoing coronary artery bypass graft surgery; observing whether these exercises can improve postoperative arterial oxygen pressure, oxygen saturation, and the distance walked in a six-minute walk test after surgery; as well as reduce hospital stay duration, lower treatment costs, and improve the quality of life as measured by the Short Form-36 Health Survey (SF-36).
Design: The study population includes patients undergoing coronary artery bypass graft surgery under general anesthesia; the research center is Capital Medical University Xuanwu Hospital; the sample size is 120.
In image-guided radiotherapy (IGRT), four-dimensional cone-beam computed tomography (4D-CBCT) is critical for assessing tumor motion during a patients breathing cycle prior to beam delivery. However, generating 4D-CBCT images with sufficient quality requires significantly more projection images than a standard 3D-CBCT scan, leading to extended scanning times and increased imaging dose to the patient. To address these limitations, there is a strong demand for methods capable of reconstructing high-quality 4D-CBCT images from a 1-minute 3D-CBCT acquisition.
View Article and Find Full Text PDFCureus
December 2024
Department of Internal Medicine, Hiroshima City Funairi Citizens Hospital, Hiroshima, JPN.
Although human metapneumovirus(hMPV) infection can induce severe symptoms in older adults or immunocompromised patients, it usually causes mild symptoms in young immunocompetent adults. The prevalence of hMPV infectious disease is highest during the late winter and early summer. We report a hypoxemic case of hMPV infection in a young immunocompetent man that occurred in the first autumn after the reclassification of coronavirus disease (COVID-19) from Class 2 to Class 5.
View Article and Find Full Text PDFPurpose: T1-weighted signal intensity ratios (SIR) comparing pancreas to spleen (SIRps) or muscle (SIRpm) can semiquantitatively assess T1 signal change associated with pancreatitis. However, there is no standardized methodology for generating these ratios. We set out to determine the impact of MRI sequence as well as region of interest (ROI) location, shape, and size on T1 SIR.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!