Surgical N95 filtering facepiece respirators (surgical N95 FFRs) are National Institute for Occupational Safety and Health-approved N95 filtering facepiece respirators (N95 FFRs) cleared by the Food and Drug Administration for resistance to liquid penetration and flammability. A recent study showed that several N95 FFR models performed as well as surgical N95 FFRs in synthetic blood penetration tests that evaluate resistance to penetration by horizontal projection. This aspect, in addition to the influence of other factors on liquid penetration, are not well studied. To address this issue, the effect of liquid volume (1 mL and 2 mL), spray velocity (450 cm/sec and 635 cm/sec), and liquid composition (synthetic blood and diluted synthetic blood) were evaluated. Four types of common protective devices were studied: N95 FFRs, surgical N95 FFRs, surgical masks, and powered air-purifying respirator (PAPR) hoods. For each protective device type, five models were analyzed using a protocol based on the F1862 ASTM International (2017) test method. Reduced liquid volume had a significant effect in only 3 of 20 models. Increased velocity had significantly greater penetration in 9 of 20 models. Diluted synthetic blood had significantly more penetration in 8 of 20 models. This last result was not expected because, in hydrostatic tests, surface tension of the diluted blood would be expected to reduce penetrability; however, across all models tested, data showed that the diluted spray was more penetrable. The study results suggest that fluid composition may be as important as velocity when considering liquid spray penetration. Furthermore, the penetrability of a spray may be inversely related to the penetrability through direct hydrostatic contact.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9468919PMC
http://dx.doi.org/10.1080/15459624.2020.1854457DOI Listing

Publication Analysis

Top Keywords

synthetic blood
20
n95 ffrs
20
surgical n95
16
blood penetration
12
n95 filtering
12
filtering facepiece
12
facepiece respirators
12
n95
9
penetration
8
liquid penetration
8

Similar Publications

Since the precursor frequency of naive T cells is extremely low, investigating the early steps of antigen-specific T cell activation is challenging. To overcome this detection problem, adoptive transfer of a cohort of T cells purified from T cell receptor (TCR) transgenic donors has been extensively used but is not readily available for emerging pathogens. Constructing TCR transgenic mice from T cell hybridomas is a labor-intensive and sometimes erratic process, since the best clones are selected based on antigen-induced CD69 upregulation or IL-2 production in vitro, and TCR chains are polymerase chain reaction (PCR)-cloned into expression vectors.

View Article and Find Full Text PDF

Aims: To develop a transformer-based generative adversarial network (trans-GAN) that can generate synthetic material decomposition images from single-energy CT (SECT) for real-time detection of intracranial hemorrhage (ICH) after endovascular thrombectomy.

Materials: We retrospectively collected data from two hospitals, consisting of 237 dual-energy CT (DECT) scans, including matched iodine overlay maps, virtual noncontrast, and simulated SECT images. These scans were randomly divided into a training set (n = 190) and an internal validation set (n = 47) in a 4:1 ratio based on the proportion of ICH.

View Article and Find Full Text PDF

Background: To investigate the toxicity of N-n-butyl haloperidol iodide (F2), a quaternary ammonium salt derivative of haloperidol, in mice for potential therapeutic purposes.

Methods: The acute median lethal dose (LD) of F2 was determined using the Bliss method following intravenous administration in mice. Routine surface electrocardiograms (ECGs) and arterial blood pressures (aBPs) were recorded under general anesthesia in untreated and pharmacologically vagotomized mice injected with F2.

View Article and Find Full Text PDF

Background/objectives: Adenoviral vector-based vaccines against COVID-19 rarely cause vaccine-induced immune thrombocytopenia and thrombosis (VITT), a severe adverse reaction caused by IgG antibodies against platelet factor 4 (PF4). To study VITT, patient samples are crucial but have become a scarce resource. Recombinant antibodies (rAbs) derived from VITT patient characteristic amino acid sequences of anti-PF4 IgG are an alternative to study VITT pathophysiology.

View Article and Find Full Text PDF

Development of Hollow Fiber Membranes Suitable for Outside-In Filtration of Human Blood Plasma.

Membranes (Basel)

January 2025

Advanced Organ Bioengineering and Therapeutics, Faculty of Science and Technology, University of Twente, Zuidhorst 28, Drienerlolaan 5, 7522 NB Enschede, The Netherlands.

Hemodialysis (HD) is a critical treatment for patients with end-stage kidney disease (ESKD). The effectiveness of conventional dialyzers used there could be compromised during extended use due to limited blood compatibility of synthetic polymeric membranes and sub-optimal dialyzer design. In fact, blood flow in the hollow fiber (HF) membrane could trigger inflammatory responses and thrombus formation, leading to reduced filtration efficiency and limiting therapy duration, a consequence of flowing the patients' blood through the lumen of each fiber while the dialysate passes along the inter-fiber space (IOF, inside-out filtration).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!