A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The benefit of fibrosa layer stripping technique during minimally invasive aortic valve replacement for calcified aortic valve stenosis-A randomized controlled trial. | LitMetric

Background: Fibrosa layer stripping (FLS) technique is a new approach to remove the calcified aortic valve. In this study, we aimed to assess the effectiveness of the FLS technique by comparing it with the conventional technique in minimally invasive aortic valve replacement (MIAVR).

Methods: A prospective, single-center, randomized controlled trial was conducted at Beijing Anzhen Hospital. Seventy patients diagnosed with severe calcific aortic stenosis were randomly assigned to undergo FLS (n = 35) or conventional (n = 35) technique to debride calcified aortic valve. Preoperative profile, procedural parameters, and postoperative outcomes were analyzed.

Results: No significant difference was observed in the preoperative profile between the two groups. Compared with the conventional technique, the FLS technique had a significantly higher indexed effective orifice area and lower mean gradient. Moreover, the FLS technique was associated with significantly reduced aortic cross-clamp time (41 [38-44] vs. 56 [51-60] min, p < .001), cardiopulmonary bypass (CPB) time (63 [56-69] vs. 81 [75-84] min, p < .001), and operative time (148 [141-156] vs. 173 [169-180] min, p < .001). Lastly, the length of intensive care unit stay (1.2 ± 0.4 vs. 1.5 ± 0.8 days, p = .041) and hospital stay (5.3 ± 0.6 vs. 6.0 ± 1.4 days, p = .020) was significantly reduced in the FLS group compared with those in the conventional group.

Conclusions: FLS technique is effective in removing calcified tissue during MIAVR and is associated with shorter cross-clamp time and CPB time, and better hemodynamic performance than the conventional technique.

Download full-text PDF

Source
http://dx.doi.org/10.1111/jocs.15215DOI Listing

Publication Analysis

Top Keywords

aortic valve
20
fls technique
16
calcified aortic
12
fibrosa layer
8
layer stripping
8
technique
8
technique minimally
8
minimally invasive
8
invasive aortic
8
valve replacement
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!