A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A newly devised flow cytometric antibody binding assay helps evaluation of dithiothreitol treatment for the inactivation of CD38 on red blood cells. | LitMetric

Background And Objectives: Anti-CD38 monoclonal antibodies, including daratumumab and isatuximab, often interfere with pretransfusion testing. Dithiothreitol (DTT) treatment of red blood cells (RBCs) negates this interference. However, the optimum DTT concentration and treatment time have not been well defined. Here, we quantified CD38 on RBCs before and after DTT treatment using a flow cytometric antibody binding assay (FABA) to specify the optimum conditions for CD38 inactivation.

Materials And Methods: For FABA, untreated or DTT-treated RBCs were incubated with fluorescein isothiocyanate-labelled anti-CD38 antibody, in the presence or absence of 100-fold or more excess of unlabelled anti-CD38 antibody, and then analysed by flow cytometry (FCM). Dissociation of CD38-positive and control histograms was determined from the D-value using the Kolmogorov-Smirnov test. The results from FABA were compared with those from conventional FCM, indirect antiglobulin test (IAT) and Western blotting.

Results: The results from FABA were more consistent than those from conventional FCM. The D-value was found to be reliable in the analysis of difference between CD38 before and after DTT treatment. Our data showed that 0·0075 mol/l DTT for 30 min is sufficient to inactivate CD38 on RBCs. These results were stable and consistent with the findings from IAT.

Conclusion: Flow cytometric antibody binding assay is an objective way of evaluating the efficacy of DTT treatment for CD38 on RBCs. This approach allows the detection of a small number of cell surface antigens and will be useful for assessing the various chemical treatments to denature RBC antigens.

Download full-text PDF

Source
http://dx.doi.org/10.1111/vox.13052DOI Listing

Publication Analysis

Top Keywords

dtt treatment
16
flow cytometric
12
cytometric antibody
12
antibody binding
12
binding assay
12
cd38 rbcs
12
red blood
8
blood cells
8
anti-cd38 antibody
8
conventional fcm
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!