Mechanical and morphological characterization of PMMA/bone composites in human femoral heads.

J Mech Behav Biomed Mater

Biomechanics Section, Department of Mechanical Engineering, KU Leuven, Leuven, Belgium. Electronic address:

Published: March 2021

PMMA bone cement has gained an important place in a variety of orthopaedic applications in the femur. However, appropriate data on the mechanical properties of bone-cement composites from the human femur are lacking. Therefore, the goal of this study was to determine the morphological and quasi-static compressive properties of proximal femoral bone-cement composites. Thirty trabecular bone specimens were extracted from fifteen pairs of human femoral heads using specimen-specific cutting guides to ensure an accurate alignment with the main trabecular direction (MTD). One specimen from each pair was augmented with PMMA bone cement, while the other one was left untreated. Specimens were scanned with μCT to determine morphological parameters and tested in quasi-static compression until failure. We found that the long axis of the specimens was highly aligned with the MTD (mean error < 5°). A higher compressive modulus and ultimate strength were observed for the bone-cement composite specimens (E = 5.7 ± 0.4 GPa; σ = 77.9 ± 5.1 MPa) compared to the bone only specimens (E = 2.9 ± 0.7 GPa; σ = 19.0 ± 5.8 MPa). Furthermore, the composites had a higher modulus, but lower strength than cement itself (E = 5.0 ± 0.3 GPa; σ = 85.9 ± 2.7 MPa) and the composite modulus was significantly correlated with the bone volume fraction (BV/TV). These results are in contrast to previous findings on human vertebral bone, where the composite was more compliant than cement and no correlation was found between BV/TV and the composite modulus. Thus, properties of bone-cement composites cannot simply be applied across different anatomical sites; the site-specific differences in bone density and trabecular alignment should be taken into account. Collectively, the present results suggest that at low BV/TV, cement dominates the composite properties, while at high BV/TV, the contribution of bone becomes apparent, revealing a positive relationship between BV/TV and the on-axis modulus.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jmbbm.2020.104247DOI Listing

Publication Analysis

Top Keywords

composites human
8
human femoral
8
femoral heads
8
pmma bone
8
bone cement
8
bone-cement composites
8
determine morphological
8
mechanical morphological
4
morphological characterization
4
characterization pmma/bone
4

Similar Publications

Background: Sedentary behaviour (SB) is detrimental to cardiometabolic disease (CMD) risk, which can begin in young adulthood. To devise effective SB-CMD interventions in young adults, it is important to understand which context-specific SB (CS-SB) are most detrimental for CMD risk, the lifestyle behaviours that cluster with CS-SBs and the socioecological predictors of CS-SB.

Methods And Analysis: This longitudinal observational study will recruit 500 college-aged (18-24 years) individuals.

View Article and Find Full Text PDF

Introduction: Donor human milk (DHM) is the first alternative if mother's own milk is unavailable or contraindicated. Much DHM research has focused on its nutritional, immunological and biochemical composition in response to various maternal variables, standard human milk banking procedures and storage protocols. The current systematic review protocol, however, aims to systematically gather and analyse existing data pertaining to the impact of these aforementioned factors on the clinical, health-related and developmental outcomes observed in infants fed with DHM.

View Article and Find Full Text PDF

Background: Recent studies show that the increase in breath hydrogen (BH) and symptoms after ingestion of inulin is reduced by co-administering psyllium.

Objectives: To determine if slowing delivery of inulin to the colon by administering it in divided doses would mimic the effect of psyllium. Primary endpoint was the BH area under the curve AUC.

View Article and Find Full Text PDF

Conductive hydrogels have great potential for applications in flexible wearable sensors due to the combination of biocompatibility, mechanical flexibility and electrical conductivity. However, constructing conductive hydrogels with high toughness, low hysteresis and skin-like modulus simultaneously remains challenging. In the present study, we prepared a tough and conductive polyacrylamide/pullulan/ammonium sulfate hydrogel with a semi-interpenetrating network.

View Article and Find Full Text PDF

Purpose: The purpose of this study is to assess the effect of perioperative testosterone supplementation on orthopedic surgical outcomes.

Methods: Three online databases were searched from database inception until September 2024. Three reviewers independently screened all titles, abstracts, and full-texts of articles investigating perioperative testosterone use in orthopedic surgery.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!