Peripheral and proximal lung ventilation in asthma: Short-term variation and response to bronchodilator inhalation.

J Allergy Clin Immunol

POLARIS, Academic Radiology, Department of Infection, Immunity and Cardiovascular Disease, University of Sheffield, Sheffield, United Kingdom.

Published: June 2021

Background: The relative involvement of the large and small airways in asthma is not clear. Hyperpolarized gas magnetic resonance imaging (MRI) provides high-resolution 3-dimensional images of ventilation distribution that can be quantified by the ventilated volume percentage (VV%) of the lungs.

Objective: Our aims were to (1) quantify the baseline reproducibility of VV%, (2) assess the ventilation distribution between the proximal and peripheral lungs, and (3) investigate regional ventilation response to bronchodilator inhalation in a cohort of patients with asthma.

Methods: A total of 33 patients with poorly controlled, moderate-to-severe asthma were scanned with hyperpolarized He MRI. Two image data sets were acquired at baseline, and 1 image data set was acquired after bronchodilator inhalation. Images were divided into proximal and peripheral regions for analysis.

Results: Bland-Altman analysis showed strong reproducibility of VV% (bias = 0.12%; LOA = -1.86% to 2.10%). VV% variation at baseline was greater in the periphery than in the proximal lung. The proximal lung was better ventilated than the peripheral lung. Ventilation increased significantly in response to bronchodilator inhalation, globally and regionally, and the ventilation increase in response to bronchodilator inhalation was greater in the peripheral lung than in the proximal lung. Hyperpolarized gas MRI was more sensitive to changes in response to bronchodilator inhalation (58%) than spirometry (33%).

Conclusion: The peripheral lung showed reduced ventilation and a greater response to bronchodilator inhalation than the proximal lung. The high level of baseline reproducibility and sensitivity of hyperpolarized gas MRI to bronchodilator reversibility suggests that it is suitable for low subject number studies of therapy response.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jaci.2020.11.035DOI Listing

Publication Analysis

Top Keywords

bronchodilator inhalation
28
response bronchodilator
24
proximal lung
20
hyperpolarized gas
12
peripheral lung
12
lung
8
lung ventilation
8
bronchodilator
8
ventilation distribution
8
baseline reproducibility
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!