The spread of SARS-CoV-2 by contact (direct or indirect) is widely accepted, but the relative importance of airborne transmission is still controversial. Probability of outdoor airborne transmission depends on several parameters, still rather uncertain: virus-laden aerosol concentrations, viability and lifetime, minimum dose necessary to transmit the disease. In this work, an estimate of outdoor concentrations in northern Italy (region Lombardia) was performed using a simple box model approach, based on an estimate of respiratory emissions, with a specific focus for the cities of Milan and Bergamo (Italy). In addition, the probability of interaction of virus-laden aerosol with pre-existing particles of different sizes was investigated. Results indicate very low (<1 RNA copy/m) average outdoor concentrations in public area, excluding crowded zones, even in the worst case scenario and assuming a number of infects up to 25% of population. On average, assuming a number of infects equal to 10% of the population, the time necessary to inspire a quantum (i.e. the dose of airborne droplet nuclei required to cause infection in 63% of susceptible persons) would be 31.5 days in Milan (range 2.7-91 days) and 51.2 days in Bergamo (range 4.4-149 days). Therefore, the probability of airborne transmission due to respiratory aerosol is very low in outdoor conditions, even if it could be more relevant for community indoor environments, in which further studies are necessary to investigate the potential risks. We theoretically examined if atmospheric particles can scavenge virus aerosol, through inertial impact, interception, and Brownian diffusion. The probability was very low. In addition, the probability of coagulation of virus-laden aerosol with pre-existing atmospheric particles resulted negligible for accumulation and coarse mode particles, but virus-laden aerosol could act as sink of ultrafine particles (around 0.01 μm in diameter). However, this will not change significantly the dynamics behaviour of the virus particle or its permanence time in atmosphere.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7833947 | PMC |
http://dx.doi.org/10.1016/j.envres.2020.110603 | DOI Listing |
J Occup Environ Hyg
January 2025
Air Pollution Research Center, Iran University of Medical Sciences, Tehran, Iran.
The pathogenic potential of airborne particles carrying the SARS-CoV-2 viral genome was examined by considering the size distribution of airborne particles at given distances from the respiratory zone of an infected patient after coughing or sneezing with a focus on time, temperature, and relative humidity. The results show an association between the size distribution of airborne particles, particularly PM and PM, and the presence of viral genome in different stations affected by the distance from the respiratory zone and the passage of time. The correlation with time was strong with all the dependent factors except PM.
View Article and Find Full Text PDFJ Infect Public Health
January 2025
Dalla Lana School of Public Health, University of Toronto, 155 College St., Toronto, Ontario M5T 3M7, Canada; Department of Civil & Mineral Engineering, 35 St. George St, Toronto, Ontario M5S 1A4, Canada.
Throughout the COVID-19 pandemic, Canadian public health advisors and politicians have shared mixed messages about the utility of portable air filters (PAFs) for mitigating the transmission of airborne infectious diseases. Some public health advisors and decision-makers have also suggested that PAFs are cumbersome or require expert advice. We take this opportunity to review evidence and address myths about PAFs.
View Article and Find Full Text PDFComput Methods Programs Biomed
January 2025
Faculty of Engineering Sciences, Kyushu University, Fukuoka, Japan.
Background And Objective: Coughing events are eruptive sources of virus-laden droplets/droplet nuclei. These increase the risk of infection in susceptible individuals during airborne transmission. The oral cavity functions as an exit route for exhaled droplets.
View Article and Find Full Text PDFSci Rep
January 2025
The Edgar L. and Harold H. Buttner Chair of Electrical Engineering and Computer Sciences, University of California, Berkeley, CA, USA.
The highly pathogenic avian influenza A(H5N1) virus threatens animal and human health globally. Innovative strategies are crucial for mitigating risks associated with airborne transmission and preventing outbreaks. In this study, we sought to investigate the efficacy of microwave inactivation against aerosolized A(H5N1) virus by identifying the optimal frequency band for a 10-min exposure and evaluating the impact of varying exposure times on virus inactivation.
View Article and Find Full Text PDFHeliyon
January 2025
Department of Building Research, Korea Institute of Civil Engineering and Building Technology, Goyang-Si, 10223, Korea.
Many COVID-19 outbreaks occurred in senior care facilities during the last three years. Senior care facilities are nursing places for the long-term treatment and care of senior citizens, who are prone to be exposed to an infectious disease that spreads into these buildings. Therefore, this study investigated airborne contaminant transmissions based on outbreak cases in senior care facilities in Korea and analyzed the potential impact of architectural features in a selected senior care facility using network simulations.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!