Background: Studies performed to date reporting outcomes after mechanical or bioprosthetic aortic valve replacement (AVR) have largely neglected the young female population. This study compares long-term outcomes in female patients aged < 50 years undergoing AVR with either a mechanical or bioprosthetic valve.

Methods: In this propensity-matched study, we compared outcomes after mechanical AVR (n = 57) and bioprosthetic AVR (n = 57) between 2004 and 2018. The primary outcome of this study is survival. Secondary outcomes include the rate of reoperation, stroke, myocardial infarction, rehospitalization for heart failure, and incidence of serious adverse events. Outcomes were measured over 15 years, with a median follow-up of 7.8 years.

Results: In patients receiving a mechanical AVR vs a bioprosthetic AVR, overall survival at median follow-up was equivalent, at 93%. There is a lower rate of reoperation in patients receiving a mechanical AVR vs a bioprosthetic AVR (1.8% vs 8.8%). The rate of new-onset atrial fibrillation was significantly higher in the mechanical AVR group vs the bioprosthetic AVR group (18.2% vs 7.3%). No significant difference was seen in the rate of serious adverse events.

Conclusions: These results provide contemporary data demonstrating equivalent long-term survival between mechanical and bioprosthetic AVR, with higher rates of new atrial fibrillation after mechanical AVR, and higher rates of reoperation after bioprosthetic AVR. These results suggest that either valve type is safe, and that preoperative assessment and counselling, as well as the follow-up, medical treatment and indications for intervention, must be a collaborative decision-making process between the clinician and the patient.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7711020PMC
http://dx.doi.org/10.1016/j.cjco.2020.06.015DOI Listing

Publication Analysis

Top Keywords

bioprosthetic avr
24
mechanical avr
20
mechanical bioprosthetic
16
avr
13
outcomes mechanical
12
mechanical
9
bioprosthetic
9
long-term outcomes
8
bioprosthetic aortic
8
aortic valve
8

Similar Publications

Background: With the rapid expansion of transcatheter aortic valve replacement (TAVR), TAVR valve explantation is also increasing. Nevertheless, previous reports on Lotus Edge valve explantation are limited to only two reports, none of which include intraoperative videos. Therefore, we report the case of an older adult who underwent a 2-year-old Lotus Edge valve explantation, after developing prosthetic valve endocarditis (PVE) and aortic annular abscess, with a strong indication for a TAVR explantation and surgical aortic valve replacement (AVR).

View Article and Find Full Text PDF

Objective: There is little evidence regarding the most beneficial choice between a mechanical and a bioprosthetic valve in the aortic position in dialysis patients. This meta-analysis compares the survival and freedom from reintervention rates between mechanical and bioprosthetic valves in patients on dialysis undergoing aortic valve replacement surgery.

Methods: Two databases were searched, and the systematic review was performed in accordance with the recommendations of the Preferred Reporting Items for Systematic Reviews and Meta-analyses statement.

View Article and Find Full Text PDF
Article Synopsis
  • Aortic valve replacement (AVR) has seen an increased use of the Perceval sutureless bioprosthesis, which shows promising safety and reliability in both short- and mid-term outcomes, with some long-term data emerging.
  • An updated systematic review of studies from 2015 to 2024 analyzed long-term outcomes of 5,221 patients with Perceval implants, revealing a long-term survival rate between 64.8% to 87.9% and low rates of complications such as structural valve degeneration and significant leaks.
  • Despite limited data on sutureless bioprostheses, the encouraging results from existing studies suggest that Perceval could provide
View Article and Find Full Text PDF

Background: Scheie syndrome, an attenuated subtype of mucopolysaccharidosis type I, is a rare storage disease that causes progressive glycosaminoglycans (GAGs) accumulation. Cardiovascular disorders determine the prognosis, and cardiac valve abnormalities are the most common cause. The patients are usually young so mechanical valve replacement is often performed, but because of the features of this disease, the surgical treatment is very risky.

View Article and Find Full Text PDF
Article Synopsis
  • Postoperative atrial fibrillation (POAF) is common after aortic valve replacement (AVR), but this study found no significant long-term risk of stroke in patients with POAF compared to those without.
  • The research analyzed 831 patients over a median of 6.5 years, focusing on those with bioprosthetic valves who were not on anticoagulation.
  • Although patients with a history of atrial fibrillation showed a higher risk of perioperative stroke, the findings suggest that POAF alone does not exacerbate long-term stroke risk in AVR patients.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!