Comparison of Longitudinal Membrane Function in Peritoneal Dialysis Patients According to Dialysis Fluid Biocompatibility.

Kidney Int Rep

Division of Nephrology, Department of Internal Medicine, Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands.

Published: December 2020

Introduction: Preservation of peritoneal function is essential in long-term peritoneal dialysis. Biocompatible dialysis solutions might prevent or postpone the membrane alteration resulting in ultrafiltration failure and consecutive morbidity and mortality.

Methods: We conducted an observational cohort study in which we made a longitudinal comparison between the course of peritoneal solute and fluid transport during treatment with conventional and biocompatible solutions. Therefore, prospectively collected peritoneal transport data from the yearly standard peritoneal permeability analysis were analyzed in 251 incident patients treated between 1994 and censoring in 2016. Fluid transport included small pore and free water transport. Solute transport was assessed by creatinine mass transfer area coefficient and glucose absorption. Linear mixed models including change point analyses were performed. Interaction with peritonitis was examined.

Results: One hundred thirty-five patients received conventional and 116 biocompatible solutions. Sixty-seven percent (conventional) and 64% (biocompatible) of these underwent minimally three transport measurements. Initially, biocompatible fluids showed higher small solute transport and lower ultrafiltration than conventional fluids up to 3 years. Thereafter, conventional fluids showed an increase in small solute transport (+2.7 ml/min per year; 95% confidence interval [CI]: 0.9 to 4.5) and a decrease of free water transport (-28.0 ml/min per year; 95% CI: -60.4 to 4.4). These were minor or absent in biocompatible treatment. Peritonitis induced a decrease of transcapillary ultrafiltration after 2 years on dialysis with conventional solutions (-291 ml/min per year; 95% CI: -550 to -32) while this was absent in biocompatible treatment.

Conclusion: Despite a higher initial solute transport with biocompatible solutions, these have less influence on functional long-term peritoneal alterations than conventional solutions.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7710881PMC
http://dx.doi.org/10.1016/j.ekir.2020.09.047DOI Listing

Publication Analysis

Top Keywords

solute transport
16
biocompatible solutions
12
ml/min year
12
year 95%
12
transport
10
peritoneal dialysis
8
long-term peritoneal
8
biocompatible
8
fluid transport
8
free water
8

Similar Publications

Organic-inorganic hybrid perovskites have demonstrated great potential for flexible optoelectronic devices due to their superior optoelectronic properties and structural flexibility. However, mechanical deformation-induced cracks at the buried interface and delamination from the substrate severely constrain the optoelectronic performance and device lifespan. Here, we design a two-site bonding strategy aiming to reinforce the mechanical stability of the SnO2/perovskite interface and perovskite layer using a multifunctional organic salt, 4-(trifluoromethoxy)phenylhydrazine hydrochloride (TPH).

View Article and Find Full Text PDF

The precise and rapid extraction of lithium from salt-lake brines is critical to meeting the global demand for lithium resources. However, it remains a major challenge to design ion-transport membranes with accurate recognition and fast transport path for the target ion. Here, we report a triazine covalent organic framework (COF) membrane with high resolution for Li+ and Mg2+ that enables fast Li+ transport while almost completely inhibiting Mg2+ permeation.

View Article and Find Full Text PDF

Lead-free halide double perovskites provide a promising solution for the long-standing issues of lead-containing halide perovskites, i.e., the toxicity of Pb and the low stability under ambient conditions and high-intensity illumination.

View Article and Find Full Text PDF

Tonoplast intrinsic proteins (TIPs) are the channel-forming proteins predominantly found in the tonoplast of plant cells. Despite the identification of TIPs in numerous plant species, very less is known about the precise role of different TIP subgroups. In the present study, two genes belonging to the TIP3 subgroup were studied to understand tissue-specific role and solute transport activity.

View Article and Find Full Text PDF

Prediction of heavy metal contamination in soil-groundwater systems at contaminated sites.

Environ Technol

January 2025

School of Civil Engineering and Architecture, Guangxi University, Nanning, People's Republic of China.

The diffusion of heavy metal pollutants in polluted industrial areas can cause severe environmental pollution in surrounding areas. However, the migration of pollutants into groundwater is a complex process that requires consideration of local geological and hydrological conditions, solute transport, and geochemistry factors to better predict the flow paths and plume dispersion of pollutants. This study is based on numerical models of Darcy's law and the Richards equation.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!