A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Sonoelastography of Normal Canine Common Calcaneal Tendon: Preliminary Results. | LitMetric

Shear wave elastography (SWE) is a feasible and newly developed ultrasonographic technique which is able to assess elasticity of tissues. The aim of this work was to assess the feasibility of SWE on the normal canine common calcaneal tendon (CCT) evaluating the intra-operator repeatability and reproducibility of single measurements and stiffness of different anatomic CCT portions was examined. Tendons were first evaluated with B-mode ultrasound with a linear probe 8.5 to 10 MHz in longitudinal section with slight flexed tarsocrural joint and a gel-pad. Common calcaneal tendon was divided into three different anatomical regions. Shear wave elastography was performed in each region by two operators and quantitative evaluation (m/s and kPa) was performed on the most representative images. Region of interest (0.15 cm) was settled. Intraclass correlation coefficient (ICC) results were classified using the following scale: 0.00 to 0.20 = poor; 0.20 to 0.40 = fair; 0.40 to 075 = good; >0.75 = excellent. Ten adult dogs were enrolled. Intra-operator ICC values were >0.75 for both operators in every tendon portion. Inter-operator SWE ICC values for m/s measurements were 0.3, 0.61 and 0.61 for the enthesis, intermediate portion and the myotendinous junction respectively; for kPa measurements, values were respectively 0.3, 0.7 and 0.81. The three CCT portions were significantly different in stiffness (-value < 0.001 for both m/s and kPa measurements). These preliminary results provide evidence that SWE is potentially appliable to assess mechanical properties of canine CCT affected by tendinopathies.

Download full-text PDF

Source
http://dx.doi.org/10.1055/s-0040-1721660DOI Listing

Publication Analysis

Top Keywords

common calcaneal
12
calcaneal tendon
12
normal canine
8
canine common
8
shear wave
8
wave elastography
8
cct portions
8
icc values
8
sonoelastography normal
4
tendon
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!