Purpose:  To evaluate the sensitivity, specificity, and interobserver reliability of high-pitch dual-source computed tomography angiography (CTA) in the detection of anomalous pulmonary venous connection (APVC) in infants with congenital heart defects and to assess the associated radiation exposure.

Materials And Methods:  78 pulmonary veins in 17 consecutively enrolled patients with congenital heart defects (6 females; 11 males; median age: 6 days; range: 1-299 days) were retrospectively included in this study. All patients underwent high-pitch dual-source CTA of the chest at low tube voltages (70 kV). APVC was evaluated independently by two radiologists. Sensitivity, specificity, positive (PPV) and negative predictive values (NPV), and interobserver agreement were determined. For standard of reference, one additional observer reviewed CT scans, echocardiography reports, clinical reports as well as surgical reports. In cases of disagreement the additional observer made the final decision based on all available information.

Results:  Detection of APVC with high-pitch dual-source CTA revealed a good sensitivity (91 %) and specificity (99 %), with PPV and NPV of 98 % and 97 %. Interobserver agreement was almost perfect (Kappa = 0.84). The median DLP was 3.8 mGy*cm (IQR 3.3-4.7 mGy*cm) and the median radiation dose was 0.33 mSv (IQR 0.26-0.39 mSv).

Conclusion:  High-pitch dual-source CTA in infants with congenital heart defects allows for accurate and reliable assessment of APVC at a low radiation dose.

Key Points:   · High-pitch dual-source CTA enables detection of anomalous pulmonary vein connection with high sensitivity in infants.. · Interrater reliability in the detection of anomalous pulmonary vein connection with high-pitch dual-source CTA is almost perfect.. · Radiation dose of high-pitch dual-source CTA in the cardiac examination of infants is low..

Citation Format: · Well L, Weinrich JM, Meyer M et al. Sensitivity of High-Pitch Dual-Source Computed Tomography for the Detection of Anomalous Pulmonary Venous Connection in Infants. Fortschr Röntgenstr 2021; 193: 551 - 558.

Download full-text PDF

Source
http://dx.doi.org/10.1055/a-1290-6843DOI Listing

Publication Analysis

Top Keywords

high-pitch dual-source
32
dual-source cta
24
anomalous pulmonary
20
detection anomalous
16
dual-source computed
12
computed tomography
12
pulmonary venous
12
venous connection
12
congenital heart
12
heart defects
12

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!