A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Temperature-induced configuration changes in hydrogel-coated coils and their relevance in embolization procedures. | LitMetric

Temperature-induced configuration changes in hydrogel-coated coils and their relevance in embolization procedures.

CVIR Endovasc

Department of Radiology and Nuclear Medicine, Luzerner Kantonsspital, 6000, Luzern, Switzerland.

Published: December 2020

Background: The present study attempted to demonstrate how the configuration of hydrogel-coated coils is influenced by different temperature exposures. Thirty detachable hydrogel-coated coils were evaluated in an in vitro water immersion test under five different temperature ranges (22.6 °C, 37 °C, 40-50 °C, 50-60 °C, and 60-70 °C). The configuration changes were classified (configuration I, configuration II, and configuration III) according to the curling that occurred during 30 min of immersion. Configuration stability of five Hydrogel-coated coils was also evaluated in a two-step temperature immersion test.

Results: All hydrogel-coated coils showed some configuration changes during water immersion. However, a logarithmic transformation of the time and temperature data showed a significant (p < 0.05) negative linear correlation between time and temperature for all coil configurations (configuration I: R = 0.97, configuration II: R = 0.98, configuration III: R = 0.97). The time needed to reach configuration III (complete coiling) was 160.4 ± 41.9 s at 37.5 °C (range: 100-205 s), 45.7 ± 22.2 s at 47.5 °C (range: 23-70 s), 20.2 ± 7.2 s at 57.5 °C (range: 14-32 s), and 10.3 ± 2.4 s at 67.5 °C (range: 7-13 s).

Conclusions: Temperatures above 55 °C induced immediate configurational changes in the hydro-coated coils, achieving complete curling within less than 30 s. Temperatures near 36 °C (normal body temperature) require more time to reach optimal coil curling (configuration III). The optimization of HydroCoil preparation can reduce interventional procedural time and improve clinical results.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7728940PMC
http://dx.doi.org/10.1186/s42155-020-00189-0DOI Listing

Publication Analysis

Top Keywords

hydrogel-coated coils
20
configuration changes
12
coils evaluated
8
water immersion
8
configuration configuration
8
configuration
7
hydrogel-coated
5
coils
5
temperature-induced configuration
4
changes hydrogel-coated
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!