Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objectives/hypothesis: The anatomy of children with severe Pierre Robin sequence can present a challenge for direct laryngoscopy and intubation. Advanced techniques including flexible fiberoptic laryngoscopic intubation have been described but require highly specialized skill and equipment. Rigid video laryngoscopy is more accessible but has not been described in this population.
Study Design: Retrospective cohort study.
Methods: A retrospective review was completed at a tertiary care center of all children between January 2016 and March 2020 with Pierre Robin sequence who underwent a mandibular distraction osteogenesis procedure. Intubation events were collected, and a descriptive analysis was performed. A univariate logistic regression model was applied to direct laryngoscopy and flexible fiberoptic laryngoscopy with rigid video laryngoscopy as a reference.
Results: Twenty-five patients were identified with a total of 56 endotracheal events. All patients were successfully intubated. Direct laryngoscopy was successful at first intubation attempt in 47.3% (9/19) of events. Six direct laryngoscopy events required switching to another device. Rigid video laryngoscopy was successful at first intubation attempt in 80.5% (29/36) of events. Two cases required switching to another device. Flexible fiberoptic laryngoscopy was found successful at first intubation attempt in 88.9% (8/9) of events. Direct laryngoscopy was 4 times more likely to fail first intubation attempt when compared to rigid video laryngoscopy (P < .05). There was no significant difference between rigid video laryngoscopy and flexible fiberoptic laryngoscopy for intubation.
Conclusions: For children with Pierre Robin sequence rigid video laryngoscopy should be considered as a first attempt intubation device both in the operating room and for emergent situations.
Level Of Evidence: 4 Laryngoscope, 131:1647-1651, 2021.