A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The TRIFLOW study: a randomised, cross-over study evaluating the effects of extrafine beclometasone/formoterol/glycopyrronium on gas trapping in COPD. | LitMetric

AI Article Synopsis

  • The study aims to understand how the components of a specific triple therapy inhaler (BDP/F/G) affect gas trapping in COPD patients.
  • The research involved 23 COPD patients and compared the effects of the triple therapy to a dual therapy (BDP/F) over multiple tests measuring lung function.
  • Results showed that BDP/F/G significantly improved lung function metrics like FEV and reduced gas trapping compared to BDP/F alone, indicating its effectiveness in treating hyperinflation in COPD.

Article Abstract

Background: The effects of triple therapy on gas trapping in COPD are not fully understood. We evaluated the effects of the long acting bronchodilator components of the extrafine single inhaler triple therapy beclometasone dipropionate/formoterol/glycopyrronium (BDP/F/G) pMDI on gas trapping.

Methods: This open-label, randomised, single centre, 2-way cross-over study recruited 23 COPD patients taking inhaled corticosteroid combination treatments and with residual volume (RV) > 120% predicted at screening. Inhaled BDP was taken during run-in and washout periods. Baseline lung function (spirometry, lung volumes, oscillometry) was measured over 12 h prior to randomisation to BDP/F/G or BDP/F for 5 days followed by washout and crossover. Lung function was measured prior to dosing on day 1 and for 12 h post-dose on day 5.

Results: Co-primary endpoint analysis: BDP/F/G had a greater effect than BDP/F on FEV area under the curve over 12 h (AUC) (mean difference 104 mls, p = 0.0071) and RV AUC (mean difference - 163 mls, p = 0.0028). Oscillometry measurements showed a greater effect of BDP/F/G on the difference between resistance at 5 and 20 Hz (R5-R20) AUC, which measures small airway resistance (mean difference - 0.045 kPa/L/s, p = 0.0002). Comparison of BDP/F with the baseline measurements (BDP alone) showed that F increased FEV AUC (mean difference 227 mls) and improved RV AUC (mean difference - 558 mls) and R5-R20 AUC (mean difference - 0.117 kPa/L/s), all p < 0.0001.

Conclusions: In COPD patients with hyperinflation, the G and F components of extrafine BDP/F/G improved FEV, RV and small airway function. These long acting bronchodilators target small airway function, thereby improving gas trapping and airflow. Trial registration The study was retrospectively registered at ClinicalTrials.gov on 15th February 2019 (No.: NCT03842904, https://clinicaltrials.gov/ct2/show/NCT03842904 ).

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7727250PMC
http://dx.doi.org/10.1186/s12931-020-01589-5DOI Listing

Publication Analysis

Top Keywords

auc difference
20
cross-over study
8
gas trapping
8
trapping copd
8
triple therapy
8
lung function
8
r5-r20 auc
8
difference
7
auc
6
triflow study
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!