A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Myocardial Injury After Balloon Predilatation Versus Direct Transcatheter Aortic Valve Replacement: Insights From the DIRECTAVI Trial. | LitMetric

Background Myocardial injury is associated with higher mortality after transcatheter aortic valve replacement (TAVR) and might be increased by prior balloon aortic valvuloplasty (BAV). We aimed to evaluate the impact of prior BAV versus direct prosthesis implantation on myocardial injury occurring after (TAVR) with balloon-expandable prostheses. Methods and Results The DIRECTAVI (Direct Transcatheter Aortic Valve Implantation) trial, an open-label randomized study, demonstrated noninferiority of TAVR without BAV (direct TAVR group) compared with systematic BAV (BAV group) with the Edwards SAPIEN 3 valve. High-sensitivity troponin was assessed before and the day after the procedure. Incidence of myocardial injury after the procedure (high-sensitivity troponin elevation >15× the upper reference limit [14 ng/L]) was the main end point. Impact of myocardial injury on 1-month adverse events (all-cause mortality, stroke, major bleeding, major vascular complications, transfusion, acute kidney injury, heart failure, pacemaker implantation, and aortic regurgitation) was evaluated. Preprocedure and postprocedure high-sensitivity troponin levels were available in 211 patients. The mean age of patients was 83 years (78-87 years), with 129 men (61.1%). Mean postprocedure high-sensitivity troponin was 124.9±81.4 ng/L in the direct TAVR group versus 170.4±127.7 ng/L in the BAV group (=0.007). Myocardial injury occurred in 42 patients (19.9%), including 13 patients (12.2%) in the direct TAVR group and 29 (27.9%) in the BAV group (=0.004). BAV increased by 2.8-fold (95% CI, 1.4-5.8) myocardial injury probability. Myocardial injury was associated with 1-month adverse events (=0.03). Conclusions BAV increased the incidence and magnitude of myocardial injury after TAVR with new-generation balloon-expandable valves. Myocardial injury was associated with 1-month adverse events. These results argue in favor of direct SAPIEN 3 valve implantation. Registration URL: https://www.Clinicaltrials.gov; Unique identifier: NCT02729519.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7955361PMC
http://dx.doi.org/10.1161/JAHA.120.018405DOI Listing

Publication Analysis

Top Keywords

myocardial injury
40
high-sensitivity troponin
16
transcatheter aortic
12
aortic valve
12
injury associated
12
direct tavr
12
tavr group
12
bav group
12
1-month adverse
12
adverse events
12

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!