Due to economic, environmental and geopolitical issues, the development of permanent magnets with a composition free of rare earth elements and with acceptable magnetic properties has been considered a priority by the international community, being MnAl based alloys amongst the most promising candidates. The aim of this work was to evaluate the toxicity of powders of two forms of newly developed MnAl(C) permanent magnets through exposure experiments applying three model organisms, using as a benchmark powders of a commercial rare-earth-containing magnet (NdFeB). For this purpose, the direct exposure to the different particles suspensions as well as to magnets leachates was evaluated. Both viability and oxidative stress assays were applied in an adenocarcinomic human alveolar basal epithelial cell line (A549) and in the yeast Saccharomyces cerevisiae, together with the bioluminescent inhibition assay in the Gram negative bacterium Vibrio fischeri. The obtained results indicate that MnAl(C) permanent magnets, in general terms, presented similar toxicity than the Nd magnet for the selected biological models under the studied conditions. Overall, the presented data provide, for the first time, an in vitro toxicity analysis of MnAl based magnets.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.chemosphere.2020.128343 | DOI Listing |
Heliyon
December 2024
Neurology Clinic, University Clinical Center of Serbia, Belgrade, Serbia.
Introduction: The hemolysis-elevated liver enzymes-low platelet counts (HELLP) syndrome and posterior reversible encephalopathy syndrome (PRES) are rare conditions that can complicate pregnancy and the early postpartum period. Although both are closely related to hypertensive pregnancy disorders, their association is rarely described, so the outcome of these patients remains unknown. We present a case report of PRES associated with HELLP syndrome and a review of all previously published cases, including demographic characteristics, clinical presentation, treatment, and outcome.
View Article and Find Full Text PDFBiomed Microdevices
January 2025
Chakri Naruebodindra Medical Institute, Faculty of Medicine Ramathibodi Hospital, Mahidol University, 111 Suwannabhumi Canal Rd, Bang Pla, Bang Phli District, Samut Prakan, 10540, Thailand.
Microfluidic chips often face challenges related to the formation and accumulation of air bubbles, which can hinder their performance. This study investigated a bubble trapping mechanism integrated into microfluidic chip to address this issue. Microfluidic chip design includes a high shear stress section of fluid flow that can generate up to 2.
View Article and Find Full Text PDFISA Trans
January 2025
Leuphana University of Lueneburg, Universitaetsallee 1, 21335 Lueneburg, Germany. Electronic address:
This paper addresses a non-interacting torque control strategy to decouple the d- and q-axis dynamics of a permanent magnet synchronous machine (PMSM). The maximum torque per ampere (MTPA) method is used to determine the reference currents for the desired torque. To realize the noninteracting control, knowledge concerning the inductances L and L of the electrical machine is necessary.
View Article and Find Full Text PDFIEEE Trans Med Robot Bionics
November 2024
Department of Cardiovascular Surgery, Boston Children's Hospital, Harvard Medical School, Boston, MA 02115, USA.
This paper introduces a novel magnetic navigation system for cardiac ablation. The system is formed from two key elements: a magnetic ablation catheter consisting of a chain of spherical permanent magnets; and an actuation system comprised of two cart-mounted permanent magnets undergoing pure rotation. The catheter design enables a large magnetic content with the goal of minimizing the footprint of the actuation system for easier integration with the clinical workflow.
View Article and Find Full Text PDFJ Hazard Mater
January 2025
Departamento de Química Orgánica y Bio-Orgánica, Universidad Nacional de Educación a Distancia (UNED), Avenida de Esparta s/n, Las Rozas de Madrid 28232, Spain. Electronic address:
Magnetite nanoparticles have been successfully used for removal and immobilization of contaminants in water, yet their application in soils combined with in situ magnetic separation remains unexplored. We evaluated the effectiveness and optimal conditions for using magnetite nanoparticles combined with magnetic separation to remove metal(loid)s from contaminated mine soils. Soil samples were incubated (15, 45 days) with varying doses of magnetite (0, 25, 50 g kg⁻¹) and moisture (dry, field capacity) and separated using electromagnet or permanent magnet.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!