Cervical disc arthroplasty (CDA) is an approved surgical treatment option in selected patients with cervical spinal disc degeneration. Even though CDA is a standard procedure since 20 years, there is a lack of information about long term performance. The published reoperation rates after CDA are low and comparable to anterior cervical fusion. The authors describe a severe failure and dysfunction with a partial core dislocation of a cervical prosthesis into the spinal canal (M6-C, Spinal Kinetics, Sunnyvale, CA, USA). Six years after implantation of a cTDR (cervical Total Disk Replacement) of the M6 type at C4/5 level, a 52 year-old women presented herself with new clinical signs of cervical myelopathy and radicular pain. Complete posterior dislocation of the central core of the implant into the spinal canal was identified as a cause. The failed device was removed completely and an ACCF (anterior cervical corpectomy and fusion) was performed. Intraoperatively, rupture of the posterior portion of the mesh tissue with posterior dislocation of the whole prosthesis core was detected. This is the second described case of a severe implant failure with core dislocation in this type of cTDR device. Even though there are thousands of successful implantations and middle term outcomes, it seems to be necessary to continue with long term radiological follow up to exclude similar failure in this type of prosthesis.

Download full-text PDF

Source
http://dx.doi.org/10.1055/a-1286-5172DOI Listing

Publication Analysis

Top Keywords

implant failure
8
cervical
8
cervical disc
8
disc arthroplasty
8
m6-c spinal
8
spinal kinetics
8
long term
8
anterior cervical
8
core dislocation
8
spinal canal
8

Similar Publications

Background: This study aimed to analyze the files of patients treated using PFN-A or INTERTAN intramedullary nails to reveal additional superiorities or disadvantageous factors for selecting the better intramedullary fixation method in patients presenting with intertrochanteric femur fractures.

Methods: In this retrospective study, the files of the patients who were operated on for intertrochanteric femur fractures using intramedullary fixation methods between September 2010 and June 2015 in the Orthopedics and Traumatology Clinic, Çukurova University Faculty of Medicine, were reviewed. The data including age, gender, chronic diseases, causes of fractures, fracture classification based on Arbeitsgemeinschaft für Osteosynthesefragen (AO), the nail type (long or short), the interval between trauma and surgery, duration of anesthesia and surgery, hospitalization duration, amount of blood transfusion, the Tip-Apex Distance (TAD) in postoperative radiographs, functional outcomes according to Harris Hip Score (HHS) and Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), postoperative complications, need for revision, and mortality was noted.

View Article and Find Full Text PDF

Background: A lateral extra-articular tenodesis (LET) is increasingly being utilized to augment an anterior cruciate ligament reconstruction because it has been shown to reduce the risk of postreconstruction graft failure or recurrent rotatory instability. Various femoral fixation techniques are available, including the use of an interference screw, staple, or suture anchor.

Purpose: To determine and compare the biomechanical properties of an LET graft when using an interference screw, staple, or suture anchor for the femoral fixation for a modified Lemaire LET.

View Article and Find Full Text PDF

Adult spinal deformity comprises a heterogeneous group of disorders that primarily affects older patients and can have a significant negative affect on health-related quality of life. Operative treatment for adult spinal deformity typically entails posterior instrumented fusions that have demonstrated the potential to significantly improve health-related quality of life outcomes. However, until fusion is achieved, the instrumentation providing structural support is subject to repetitive cyclical loading that disproportionately fatigues high-stress areas and can result in instrumentation failure.

View Article and Find Full Text PDF

Introduction: Dental implants are routinely used to replace missing teeth. Therefore, the primary aim of the present study was to assess the single-unit implant failure rate over a period of seven years from 2015 to 2021, with a minimum of two years post-implant follow-up. The secondary aim was to identify the risk factors associated with implant failure using machine learning decision tree regression and Kaplan-Meier survival analyses.

View Article and Find Full Text PDF

Minimum twenty-year follow-up of fixed-vs mobile-bearing total knee arthroplasty: Double blinded randomized trial.

J Clin Orthop Trauma

January 2025

Loyola University Health System, Department of Orthopaedic Surgery and Rehabilitation, 2160 South First Avenue, 60153, Maywood, IL, USA.

Introduction: Mobile-bearing (MB) inserts, designed to minimize aseptic loosening and to reduce contact stresses leading to polyethylene wear, are an alternative to fixed-bearing (FB) inserts. Most studies have shown no significant difference between MB and FB constructs, and there is limited long-term data comparing the two constructs [1,2,3,4]. The purpose of this study was to report the outcomes of a randomized controlled trial comparing MB versus FB inserts on patients with minimum 20-year follow-up.

View Article and Find Full Text PDF