Purpose: In upper brachial plexus injury (UBPI), restoring shoulder function is crucial. This study compares the transfer of long and lower medial heads of triceps branches to the axillary nerve to achieve proper restoration of function.
Patients And Methods: A retrospective comparative study was conducted between two groups of patients with (UBPI). Group I patients (10) [mean age: 19 ± 10.6 years] were managed by transferring triceps long head branch to axillary nerve while group II patients (8) [mean age: 26 ± 9.6 years] were managed by triceps lower medial head branch transfer. The mean time from injury to surgery was 6 ± 1.3 and 5 ± 1.7 months respectively. All patients were followed up for a minimum of 12 months with the assessment of VAS, DASH score, active range of motion (AROM) and strength of shoulder abduction and external rotation; in addition to shoulder endurance and strengths of donors. Postoperative, three-monthly, electrodiagnostic assessments were performed.
Results: Postoperatively, the mean VAS and DASH scores; in addition to endurance time, showed significant enhancement in both groups. Patients in both groups have accomplished a mean abduction (AROM) of 98° ± 27.9 and 97° ± 11.9 respectively. The mean external rotation (AROM) was 48° ± 18.4 and 47° ± 9.2 respectively. Furthermore, group II patients had less triceps morbidity in addition to earlier and enhanced electrophysiological recovery.
Conclusions: Dual neurotization for shoulder function restoration in (UBPI) is capable of providing proper functional results with minimal donor morbidity. The triceps lower medial branch provides an excelling donor due to less triceps morbidity, extra length; yet, earlier and enhanced electrophysiological recovery.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/micr.30690 | DOI Listing |
J Med Radiat Sci
January 2025
Discipline of Medical Imaging Sciences, Faculty of Medicine and Health, University of Sydney, Camperdown, New South Wales, Australia.
Introduction: Quality assurance (QA) in medical imaging ensures consistently high-quality images at acceptable radiation doses. However, the applicability of the chest X-ray (CXR) QA tool in images with pathology, particularly infectious diseases like COVID-19, has not been explored. This study examines the utility of the European Guidelines for image quality in QA of CXRs with varying severity and types of infectious disease.
View Article and Find Full Text PDFWorld J Orthop
December 2024
Department of Orthopaedic Surgery and Traumatology, Cantonal Hospital Sankt Gallen, Sankt Gallen 9007, Switzerland.
Background: When patients with a failed hip arthroplasty are unsuitable for reimplantation, Girdlestone resection arthroplasty (GRA) is a viable treatment option. We report on a patient who was treated with a GRA due to a periprosthetic infection. We discovered partial paralysis of the quadriceps muscle in this patient.
View Article and Find Full Text PDFWorld J Orthop
December 2024
Department of Orthopaedic Surgery, Massachusetts General Hospital, Boston, MA 02114, United States.
Background: Pes planus (flatfoot) and pes cavus (high arch foot) are common foot deformities, often requiring clinical and radiographic assessment for diagnosis and potential subsequent management. Traditional diagnostic methods, while effective, pose limitations such as cost, radiation exposure, and accessibility, particularly in underserved areas.
Aim: To develop deep learning algorithms that detect and classify such deformities using smartphone cameras.
Imaging Sci Dent
December 2024
Department of Oral Diagnosis, Division of Oral Radiology, Piracicaba Dental School, University of Campinas, Piracicaba, SP, Brazil.
Purpose: This study was performed to evaluate the expression of beam hardening artifacts generated by high atomic number materials in stitched cone-beam computed tomography (CBCT) images, compared to the traditional acquisition mode.
Materials And Methods: CBCT volumes were acquired using an acrylic resin phantom embedded with pairs of cylinders made from amalgam dental alloy, cobalt-chromium alloy, gutta-percha, titanium, and zirconium. These cylinders were placed within the overlapping zones of the stitching reconstruction area.
Zhonghua Yan Ke Za Zhi
January 2025
Tianjin Eye Hospital, Nankai University Affiliated Eye Hospital, Clinical College of Ophthalmology of Tianjin Medical University, Tianjin Eye Institute, Tianjin Key Laboratory of Ophthalmology and Visual Science, Tianjin300020, China.
To explore the efficacy of the modified lateral rectus muscle splitting and nasal transposition surgery in treating large-angle exotropia caused by oculomotor nerve palsy and its impact on ocular motility. Retrospective case series study. Data was collected from patients diagnosed with large-angle exotropia due to oculomotor nerve palsy and treated by modified lateral rectus muscle splitting and nasal transposition surgery at the Tianjin Eye Hospital from January 2020 to October 2023.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!