A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Advanced Medical Devices for Preparation and Administration of Chemotherapeutic Agents: Results from a Multi-Dimensional Evaluation. | LitMetric

Purpose: To evaluate the incremental benefits concerning the implementation of closed-system medical devices for the preparation and administration of chemotherapy agents (integrated or not with traceable workflow), within an Italian clinical practice, in which the use of such technologies is not standardized.

Methodology: Four Scenarios, implying different levels of technologies introduction, were analyzed, based on the presence and/or absence of closed systems and traceable workflow, in the preparation and in the administration phase. A literature review was conducted, in order to retrieve efficacy and safety measures. Economic and organizational benefits, assuming a hospitals perspective, were assessed by means of health-economics tools, considering 27,660 (±695.86) drugs on average prepared, on an annual basis, by 12 hospitals involved. The typology of medical devices and other devices/equipment used, the human resources involved, and the time spent for the preparation and administration phases were collected.

Results: Literature stated that the introduction of advanced technologies (CSTDs in the preparation phase, closed-system in the administration phase, both integrated by a traceable workflow) could: i) decrease surface contamination (12.24% vs 26.39%, <0.001) and ii) improve the capability to identify dosage errors (7% vs 0.096%, <0.05). The above technologies presented the best trade-off between cost sustained and efficacy gained. Despite marginal investments (ranging from +1% to +6%) being required for their acquisition, an organizational saving equal to more than 1,000 working hours emerged, which could be spent on other hospital activities.

Conclusion: The implementation of closed systems, integrated with a traceable workflow grounding on gravimetric control, may be considered a valid technological alternative within the investigated setting. The marginal incremental costs could be absorbed already in the first year after their introduction, in particular, because of the potential time saving in using closed systems in both the preparation and administration phases, demonstrating the sustainability and feasibility of such advanced technologies.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7718866PMC
http://dx.doi.org/10.2147/CEOR.S267283DOI Listing

Publication Analysis

Top Keywords

preparation administration
16
medical devices
12
traceable workflow
12
devices preparation
8
integrated traceable
8
administration phase
8
preparation
5
administration
5
advanced medical
4
administration chemotherapeutic
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!