A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

High-Flow Nasal Cannula Therapy for Exertional Dyspnea in Patients with Cancer: A Pilot Randomized Clinical Trial. | LitMetric

Background: Exertional dyspnea is common in patients with cancer and limits their function. The impact of high-flow nasal cannula on exertional dyspnea in nonhypoxemic patients is unclear. In this double-blind, parallel-group, randomized trial, we assessed the effect of flow rate (high vs. low) and gas (oxygen vs. air) on exertional dyspnea in nonhypoxemic patients with cancer.

Patients And Methods: Patients with cancer with oxygen saturation >90% at rest and exertion completed incremental and constant work (80% maximal) cycle ergometry while breathing low-flow air at 2 L/minute. They were then randomized to receive high-flow oxygen, high-flow air, low-flow oxygen, or low-flow air while performing symptom-limited endurance cycle ergometry at 80% maximal. The primary outcome was modified 0-10 Borg dyspnea intensity scale at isotime. Secondary outcomes included dyspnea unpleasantness, exercise time, and adverse events.

Results: Seventy-four patients were enrolled, and 44 completed the study (mean age 63; 41% female). Compared with low-flow air at baseline, dyspnea intensity was significantly lower at isotime with high-flow oxygen (mean change, -1.1; 95% confidence interval [CI], -2.1, -0.12) and low-flow oxygen (-1.83; 95% CI, -2.7, -0.9), but not high-flow air (-0.2; 95% CI, -0.97, 0.6) or low-flow air (-0.5; 95% CI, -1.3, 0.4). Compared with low-flow air, high-flow oxygen also resulted in significantly longer exercise time (difference + 2.5 minutes, p = .009), but not low-flow oxygen (+0.39 minutes, p = .65) or high-flow air (+0.63 minutes, p = .48). The interventions were well tolerated without significant adverse effects.

Conclusion: Our preliminary findings support that high-flow oxygen improved both exertional dyspnea and exercise duration in nonhypoxemic patients with cancer. (ClinicalTrials.gov ID: NCT02357134).

Implications For Practice: In this four-arm, double-blind, randomized clinical trial examining the role of high-flow nasal cannula on exertional dyspnea in patients with cancer without hypoxemia, high-flow oxygen, but not high-flow air, resulted in significantly lower dyspnea scores and longer exercise time. High-flow oxygen delivered by high-flow nasal cannula devices may improve clinically relevant outcomes even in patients without hypoxemia.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8342581PMC
http://dx.doi.org/10.1002/onco.13624DOI Listing

Publication Analysis

Top Keywords

exertional dyspnea
24
high-flow oxygen
24
patients cancer
20
low-flow air
20
high-flow nasal
16
nasal cannula
16
high-flow air
16
high-flow
14
nonhypoxemic patients
12
low-flow oxygen
12

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!