A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Precontoured Plate Fixation for Incomplete Atypical Diaphyseal Fracture of Femur using Three-Dimensional Printing Rapid Prototyping: Two Cases Reports. | LitMetric

Background: Reconstruction intramedullary nail spanning the whole length of the femur has been the gold standard treatment for complete atypical diaphyseal fractures of the femur (ADF). However, in cases of incomplete ADF combined with severe bowing, this approach might have complications and lead to iatrogenic complete fracture. We report two cases of incomplete ADF with severe bowing using a precontoured plate (PCP) after rapid prototyping (RP) of the deformed femurs with three-dimensional printing (3DP) technology.

Case Presentation: Two patients presented with gradually worsening thigh pain, especially during walking. The patients had been using bisphosphonates for 4 and 10 years, respectively. Radiography showed an incomplete fracture in the lateral cortex of the right femur shaft. The lateral bowing angles measured in the affected femurs were 15° and 14°, and the anterior bowing angles were 20° and 16°, respectively. In bone scans, both patients showed hot uptake in the right mid-shaft of the femur. Preoperatively, the affected femur of the patient was reconstructed by 3DP RP using CT, and the plate was bent to the shape of the bone model. The ADF was fixed with a PCP using the minimally invasive plate osteosynthesis technique. Both patients were encouraged to start full weight-bearing and return to their preinjury activity level in daily life immediately after surgery. At 2 years postoperatively, radiography showed healing of the fracture site without recurrence of thigh pain and implant-related problems.

Conclusion: Although intramedullary nailing is the standard surgical treatment for complete ADF, PCP using 3DP RP could be an effective treatment option for incomplete ADF with severely curved femur.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7862140PMC
http://dx.doi.org/10.1111/os.12867DOI Listing

Publication Analysis

Top Keywords

incomplete adf
12
precontoured plate
8
atypical diaphyseal
8
three-dimensional printing
8
rapid prototyping
8
treatment complete
8
cases incomplete
8
severe bowing
8
thigh pain
8
bowing angles
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!