A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Insights into Enhanced Repeatability of Femtosecond Laser-Induced Plasmas. | LitMetric

Insights into Enhanced Repeatability of Femtosecond Laser-Induced Plasmas.

ACS Omega

State Key Lab of Power Systems, Department of Energy and Power Engineering, Tsinghua University, Beijing 100084, China.

Published: December 2020

Repeatability is of utmost importance as it is directly linked to measurement accuracy and precision of a technique and affects its cost, utility, and commercialization. The present paper contributes to explain enhanced repeatability of the femtosecond laser-induced breakdown spectroscopy (fs-LIBS) technique, remarkably significant for its industrial applications and instrumental size reduction. A fs-laser with 7 mJ pulse energy was focused to create a transient titanium plasma, and a high-resolution spectrometer was used to study time-resolved spectra and single-shot drilling sampling repeatability. Time-resolved spectroscopy study at a delay time interval of 0-1600 ns showed 200-400 ns as the optimum delay time zone for data acquisition with 2-4% line intensity RSDs. Plasma temperature RSDs were <1.8% for the investigated delay interval and reached 0.5% at 200 ns where the temperature recorded a maximum value of 22,000 K. Electron density reached 5.7 × 10 cm at 200 ns, and RSDs were <3% with the least fluctuation of 0.7%. Shot-to-shot RSDs were 3.5-5% at 15-30 drilling shot intervals for line intensities, <2% for plasma temperature, and <6.5% for electron density. Using an uncertainty propagation formula, total number density RSDs were calculated to be 1.9-5.3% for 50 single-shot drilling scenarios. Considering physics behind results, fs-plasmas are "stable ablation sources" due to their electrostatic formation mechanisms and confined hydrodynamic evolution. The fs-laser opens up new directions for LIBS applications where accuracy is significantly enhanced.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7711694PMC
http://dx.doi.org/10.1021/acsomega.0c03636DOI Listing

Publication Analysis

Top Keywords

enhanced repeatability
8
repeatability femtosecond
8
femtosecond laser-induced
8
delay time
8
insights enhanced
4
repeatability
4
laser-induced plasmas
4
plasmas repeatability
4
repeatability utmost
4
utmost directly
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!