Background: We describe the technical report and results of the first image-guided, linear accelerator, frameless radiosurgical third ventriculostomy.

Methods: We report a 20 years old man, with diplopia, balance disturbances, and limitation for gaze supraversion. Magnetic resonance imaging resonance imaging of the brain and cranial computed tomography showed showed a left thalamic-midbrain lesion that caused partial compression of the Silvio aqueduct and mild ventricular dilatation. The biopsy revealed the diagnosis of pleomorphic xanthoastrocytoma. Before radical treatment of the tumor with fractionated stereotactic radiotherapy, the patient underwent to frameless radiosurgical third ventriculostomy, on the TrueBeam STX® platform with the ExacTrac localization system. The target used was the one defined on the floor of the third ventricle, at the midpoint between the mammillary bodies and the infundibular recess. The prescription dose was 120 Gy, given using a monoisocentric technique of multiple noncoplanar circular arches. The geometric arrangement of the plan consisted of 15 arches, with a 4 mm cone, distributed over a 110° table.

Results: There was symptomatic and image improvement two days after radiosurgery. On CT, a reduction in ventricular dilation was observed with a reduction in the Evans index from 0.39 (initial CT) to 0.29 (CT at 15 days). In 3.0T magnetic resonance image at 3 months, we showed the third ventriculostomy. There have been no treatment failures or complications.

Conclusion: It is possible to effectively perform the frameless radiosurgical third ventriculostomy without associated morbidity in the short term.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7710479PMC
http://dx.doi.org/10.25259/SNI_247_2020DOI Listing

Publication Analysis

Top Keywords

frameless radiosurgical
16
radiosurgical third
16
third ventriculostomy
16
technical report
8
magnetic resonance
8
resonance imaging
8
third
6
frameless
4
ventriculostomy
4
ventriculostomy technical
4

Similar Publications

Purpose: Development of a simple, phantom-based methodology allowing for pilot applications for the Elements TPS cranio-vascular module and clinical implementation prior to AVM treatments.

Methods: A customized phantom was developed to be visible in MRI and CT images. High resolution digital subtraction angiograms (DSAs) and CT images of the phantom were acquired and imported into the Brainlab Elements treatment planning system.

View Article and Find Full Text PDF

Purpose: Effective treatment options for refractory depression are needed. Recent advancements permit both precise ablative radiation and functional neurologic connectome analysis using standard magnetic resonance imaging. We combined these innovations to perform stereotactic radiosurgical capsulotomy for the treatment of medically refractory major depressive disorder and study connectome response using a novel tractography-based approach.

View Article and Find Full Text PDF

Purpose: We sought to determine whether a more widely accessible, noninvasive, frameless approach to radiosurgical thalamotomy would improve objective measures of refractory essential or parkinsonian tremor without added toxicity compared with reports of frame-based radiosurgery.

Methods And Materials: We conducted a single-arm pilot observational prospective trial of adult patients with essential or parkinsonian tremor from 2013 to 2019 and report results at 1-year follow-up. Patients were treated with frameless unilateral radiosurgical ablation of the thalamic ventral intermediate nucleus to a maximum dose of 160 Gy.

View Article and Find Full Text PDF

Objective: The present study aimed to examine the technical feasibility and effectiveness of adapting the radiation dose distributions with three-dimensional (3D) linear couch translations in contrast to full six-dimensional couch maneuvers to correct for rotational shifts during frameless radiosurgical treatment with the Gamma Knife Icon™ (Elekta AB; Stockholm, Sweden).

Methods: The original magnetic resonance images used for radiosurgery treatment planning (15 targets) were digitally processed to simulate rotational shifts of ±1, ±2, ±3, ±5, and ±10 degrees in the transverse plane and imported back into Leksell GammaPlan (Elekta AB), creating "uncorrected" treatment plans. In addition, geometrically optimized 3D translation shifts were consequently applied to each isocenter in all "uncorrected" treatment plans to account for systematically introduced rotational shifts and to produce "corrected" treatment plans.

View Article and Find Full Text PDF

Background: We describe the technical report and results of the first image-guided, linear accelerator, frameless radiosurgical third ventriculostomy.

Methods: We report a 20 years old man, with diplopia, balance disturbances, and limitation for gaze supraversion. Magnetic resonance imaging resonance imaging of the brain and cranial computed tomography showed showed a left thalamic-midbrain lesion that caused partial compression of the Silvio aqueduct and mild ventricular dilatation.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!