Background: To evaluate the influence of the association of the universal adhesive system to different energy densities of the Nd:YAG laser on the hydraulic conductance of dentin.

Material And Methods: Fifty bovine dentin discs were made. The samples were stratified into four groups (n = 10) according to the treatment performed; SBU- Adper Single Bond Universal (3M ESPE), SBU_60 - SBU associated with the Nd:YAG laser (60mJ, 10Hz, 0.6W - 47.77 J / cm²), SBU_80 - SBU associated with the Nd:YAG laser (80mJ, 10Hz, 0.8 W - 63.69 J / cm2) and C - dentin without treatment (smear layer). Hydraulic conductance measurements were taken 24 hours after the treatments (HC1) and after erosive challenge (HC2). Scanning electron microscopy (SEM) and energy dispersive X-ray spectrometry (EDX) helped to visualize the dentin after the different treatments. Scheffe and Games-Howell statistical tests were used to analyze hydraulic conductance (α = 0.05).

Results: The treated dentin (SBU, SBU_60, and SBU_80) reduced HC1 when compared to dentin with smear layer (C) (< 0.001). The erosive challenge has increased HC2 in SBU_60 and C (< 0.001), and did not promote a significant difference in SBU_80 and SBU. The SEM / EDX analyzes showed an irregular and semi-permeable barrier on the surfaces of the treated dentin.

Conclusions: The association of universal adhesive with Nd:YAG can be an effective alternative for the occlusion of dentinal tubules, whereas higher energy per pulse Nd:YAG (SBU_80) can increase the resistance to permeability when exposed to the erosive challenge. Dentin, permeability of dentin, Nd:YAG Laser, adhesives.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7700791PMC
http://dx.doi.org/10.4317/jced.57306DOI Listing

Publication Analysis

Top Keywords

ndyag laser
20
universal adhesive
12
hydraulic conductance
12
erosive challenge
12
adhesive system
8
dentin
8
association universal
8
sbu associated
8
associated ndyag
8
sbu_80 sbu
8

Similar Publications

Treatment of onychomycosis includes topical and systemic agents. However, prolonged use of oral treatment could cause adverse effects and topical antifungal agents have limited penetration. To compare the clinical efficacy and the safety of fractional CO laser combined with topical tioconazole nail solution versus Q-switched 1064 Nd: YAG laser in the treatment of fingernail onychomycosis.

View Article and Find Full Text PDF
Article Synopsis
  • Melasma is a common, chronic skin condition that mainly affects women, presenting as dark patches on the face and is often perceived as a serious cosmetic issue.
  • A survey conducted among 199 dermatologists in Turkiye revealed that the majority of patients with melasma are females between the ages of 30 to 40, with mixed melasma being the most common type.
  • The study found that topical treatments, particularly Kligman's formula, are most frequently used, while oral treatments like tranexamic acid are less common, and there's a significant recurrence rate of 41%-60%, suggesting the need for better management strategies.
View Article and Find Full Text PDF

Anion photoelectron spectra of ThSO- and ThS2- were recorded using the third (355 nm) harmonic of an Nd-YAG laser; these provided the measured vertical detachment energies of each anion. The experiments are supported by extensive coupled cluster calculations on ThSO, ThSO-, ThS2, and ThS2-, as well as the oxygen congeners ThO2 and ThO2-. The ab initio calculations, which included complete basis set extrapolations, spin-orbit effects using four-component coupled cluster, and higher-order correlation contributions through CCSDT(Q), yielded an adiabatic electron affinity for ThO2 that was within 0.

View Article and Find Full Text PDF

Plasma focus devices represent a class of hot and dense plasma sources that serve a dual role in fundamental plasma research and practical applications. These devices allow the observation of various phenomena, including the z-pinch effect, nuclear fusion reactions, plasma filaments, bursts, shocks, jets, X-rays, neutron pulses, ions, and electron beams. In recent years, considerable efforts have been directed toward miniaturizing plasma focus devices, driven by the pursuit of both basic studies and technological advancements.

View Article and Find Full Text PDF
Article Synopsis
  • The study looked at the risks of retinal detachment (RD) after a specific eye surgery called Boston Type 1 Keratoprosthesis (B1KPro) during the first year and beyond.
  • They found that 29% of patients experienced RD, with most cases happening within the first year (21%) and fewer later (7%).
  • Important risk factors for early RD included low eye pressure (hypotony), previous eye surgeries, and certain eye conditions, while changes in the retina before surgery were linked to later RD.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!