A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Ultrasensitive mercury ion and biothiol detection based on Dansyl-His-Pro-Gly-Asp-NH fluorescent sensor. | LitMetric

Ultrasensitive mercury ion and biothiol detection based on Dansyl-His-Pro-Gly-Asp-NH fluorescent sensor.

Spectrochim Acta A Mol Biomol Spectrosc

School of Chemistry and Chemical Engineering, Liaocheng University, Liaocheng, China. Electronic address:

Published: April 2021

Mercury is an environmental contaminant, which is highly toxic even at extremely low concentrations. Long-term accumulation of mercury in human body will damage the central nervous system or digestive tract system. Here, a new fluorescent chemical sensor Dansyl-His-Pro-Gly-Asp-NH (D-P4) was synthesized for the determination of Hg. The D-P4 sensor exhibits excellent selectivity and sensitivity to Hg in aqueous solution with a 'turn-off' fluorescence response. Furthermore, D-P4-Hg system displays a good 'turn-on' fluorescence response to biothiols. The calculated binding constant for the 1:1 complex of D-P4 with Hg is 1.07 × 10 M, which also confirms the high affinity of D-P4 for Hg. Results indicate that the detection limit of D-P4 for Hg is 61.0 nM, and that of D-P4-Hg system for Cys is as low as 80.0 nM.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.saa.2020.119246DOI Listing

Publication Analysis

Top Keywords

fluorescence response
8
d-p4-hg system
8
d-p4
5
ultrasensitive mercury
4
mercury ion
4
ion biothiol
4
biothiol detection
4
detection based
4
based dansyl-his-pro-gly-asp-nh
4
dansyl-his-pro-gly-asp-nh fluorescent
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!