Numerical analysis of the pulsating heat source effects in a tumor tissue.

Comput Methods Programs Biomed

Dipartimento di Medicina e Scienze della Salute "Vincenzo Tiberio", UniversitĂ  del Molise, Via Francesco De Sanctis 1, 86100, Campobasso, ITALY.

Published: March 2021

Background And Objectives: Hyperthermia treatment is nowadays recognized as the fourth additional cancer therapy technique following surgery, chemotherapy, and radiation; it is a minimally or non-invasive technique which involves fewer complications, a shorter hospital stay, and fewer costs. In this paper, pulsating heat effects on heat transfer in a tumor tissue under hyperthermia are analyzed. The objective of the paper is to find and quantify the advantages of pulsatile heat protocols under different periodical heating schemes and for different tissue morphologies.

Methods: The tumor tissue is modeled as a porous sphere made up of a solid phase (tissue, interstitial space, etc.) and a fluid phase (blood). A Local Thermal Non-Equilibrium (LTNE) model is employed to consider the local temperature difference between the two phases. Governing equations with the appropriate boundary conditions are solved with the finite-element code COMSOL Multiphysics®. The pulsating effect is modeled with references to a cosine function with different frequencies, and such different heating protocols are compared at equal delivered energy, i. e. different heating times at equal maximum power.

Results: Different tissue properties in terms of blood vessels sizes and blood volume fraction in tissue (porosity) are investigated. The results are shown in terms of tissue temperature and percentage of necrotic tissue obtained. The most powerful result achieved using a pulsating heat source instead of a constant one is the decreasing of maximum temperature in any considered case, even reaching about 30% lower maximum temperatures. Furthermore, the evaluation of tissue damage at the end of treatment shows that pulsating heat allows to necrotize the same tumoral tissue area of the non-pulsating heat source.

Conclusions: Modeling pulsating heat protocols in thermal ablation under different periodical heating schemes and considering different tissues morphologies in a tumor tissue highlights how the application of pulsating heat sources allows to avoid high temperature peaks, and simultaneously to ablate the same tumoral area obtained with a non-pulsating heat source. This is a powerful result to improve medical protocols and devices in thermal ablation of tumors.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.cmpb.2020.105887DOI Listing

Publication Analysis

Top Keywords

pulsating heat
24
tumor tissue
16
heat source
12
tissue
12
heat
10
heat protocols
8
periodical heating
8
heating schemes
8
powerful result
8
area non-pulsating
8

Similar Publications

Comparative analysis of the silver-gold and copper-titanium dioxide hybrid nanoparticles impact on flow and heat transfer of the pulsatile blood in occluded cerebral artery.

J Therm Biol

January 2025

Department of Mechanics, Electrical Power and Computer, Science and Research Branch, Islamic Azad University, Tehran, Iran; Department of Mechanical Engineering, University of Kurdistan, Sanandaj, Iran. Electronic address:

Arterial stenosis, which is the progressive narrowing of the lumen of blood vessels, severely compromises perfusion and leads to complex hemodynamic alterations. Evolving to address this challenge, hybrid nanofluids have emerged as a truly transformative solution due to their superior thermal and fluid properties. The present study numerically investigates the flow and heat transfer phenomena of two hybrid nanofluids, namely Silver-Gold (Ag-Au) and Copper-Titanium dioxide (Cu-TiO), in a bifurcated artery with 50% stenosis.

View Article and Find Full Text PDF

Ultrasound-induced thermal strain imaging (US-TSI) is a promising ultrasound imaging modality that has been demonstrated in preclinical studies to identify a lipid-rich necrotic core of an atherosclerotic plaque. However, human physiological motion, e.g.

View Article and Find Full Text PDF

A closed-loop pulsating heat pipe (CLPHP) is an attractive passive cooling system for electronic components. The design of CLPHP is challenging due to the complex nature of thermo-hydrodynamic coupling. This study investigates the heat transfer efficiency of a CLPHP using water as the working fluid.

View Article and Find Full Text PDF

Objectives: Irreversible Electroporation (IRE) is a non-thermal minimally invasive cancer therapy used in the treatment of liver tumors. However, the therapy entails an electrical current flux which can be high enough to cause a noticeable temperature increase. Therefore, the analysis of the heat distribution is important: during any IRE treatment, the target area is intended to be treated with non-thermal effects, where existing thermal effects should not damage nearby sensitive structures.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?