Introduction: We examined the endosteal and periosteal circulations in a patient with fracture non-union who had undergone excessive osteosynthesis applications (two long plates had been placed medially and laterally on the left tibia extending from the proximal 2/7 to the distal 6/7 parts of the bone, while a tibial component of a total knee prosthesis with a long stem had been inserted at the same time).
Methods: Concomitant perfusion changes were determined in the anterolateral and anteromedial periosteal sheath of the non-united bone ends and intramedullary nearest the osteosynthesis materials during their surgical removal on re-operation. The blood flow in the periosteum and endosteum was recorded by a laser-Doppler flowmetric device using a novel approach. Control measurements were made at identical points of the right tibia.
Results: Considerably lower blood flow values were measured along the tibial periosteal region of the re-operated limb than on the contralateral side (the average perfusion unit (PU) was 76 vs. 106 PU, respectively). Perfusion values were markedly lower in the endosteal region (average values of approx. 30 PU) in the control tibia and were even more diminished in the re-operated tibial endosteum (average 9 PU).
Conclusions: Our study was conducted to characterize the microcirculatory changes of a long bone in response to intramedullary implantation and to provide quantitative data on the insufficiency of local perfusion in a patient with fracture non-union. Our results highlight the association between local perfusion failure and the unfavorable outcome (i.e. fracture non-union), confirming that the vital aspects of the microcirculation should not be disregarded when aiming for mechanical stability. Microcirculatory measurements constitute a new area of improvement in planning the adequate treatment for fracture non-unions with an unclear aetiology. Further refinement of the laser-Doppler technique could have potential benefits for bone surgery and postoperative trauma care in the future.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.injury.2020.11.053 | DOI Listing |
Eur J Orthop Surg Traumatol
December 2024
University Hospitals Cleveland Medical Center, Cleveland, USA.
Purpose: Olecranon osteotomy has been associated with loss of reduction, nonunion, implant failure, and migration of wires. We aim to evaluate quality of reduction of the osteotomy site as a predictor of olecranon osteotomy nonunion.
Methods: One hundred and twenty-five distal humerus fractures that underwent open reduction internal fixation (ORIF) were reviewed.
BMC Musculoskelet Disord
December 2024
Department of Joint Surgery, The Affiliated Hospital of Qingdao University, No. 59, Haier Road, Laoshan District, Qingdao, 266100, Shandong, People's Republic of China.
Background: Venous thromboembolism (VTE) is a common complication after hip arthroplasty. Here, we investigated the clinical efficacy and safety of prophylactic aspirin vs. conventional therapy in hip arthroplasty for femoral neck fracture.
View Article and Find Full Text PDFJ Funct Biomater
December 2024
Innovative Implant Development (Fracture Healing), Departments and Institutes of Surgery, Saarland University, 66421 Homburg, Germany.
Bone fractures are associated with hypoxia, but no longitudinal studies of perfusion measurements in human patients have been reported despite the clinical and research potential. In this longitudinal observational cohort study, the near-infrared spectroscopy (NIRS) device PortaMon was used to assess oxy-(OHb), deoxy-(HHb) and total (tHb) haemoglobin, as well as the differences between OHb and HHb (Hb) and the tissue saturation index (TSI) at three different depths in the fracture gap. Linear mixed effect models were fitted to analyse time effects.
View Article and Find Full Text PDFGeorgian Med News
October 2024
2Samarkand branch of the State Institution "Republican Specialized Scientific and Practical Medical Center for Traumatology and Orthopedics of the Ministry of Health of the Republic of Uzbekistan", Samarkand, Republic of Uzbekistan.
Introduction: The lack of standardization in the assessment of healing potential of diaphyseal tibial fractures in the early stages of treatment leads to late diagnosis of non-union, which requires the development of prognostic diagnostic criteria that take into account possible risk factors.
Objective: To analyze and evaluate the available scoring systems for predicting union and non-union of diaphyseal tibial fractures.
Methods: We searched for publications in Scopus (Elsevier), PubMed, Publons, Medline, RSCI, Google, and Google Scholar databases.
Arch Orthop Trauma Surg
December 2024
Department of Orthopaedic Surgery, Korea University Guro Hospital, 148 Gurodong-ro, Guro- gu, Seoul, 08308, Korea.
Introduction: Although sesamoid-preserving procedures have been attempted to complement sesamoidectomy for hallux sesamoid fracture nonunion, few reports document the results. Accordingly, the objective of this study was to review the outcomes of patients with hallux sesamoid fracture nonunion who underwent screw fixation with autogenous bone grafting.
Materials And Methods: Medical records of patients who underwent surgery between January 2013 and September 2022 were reviewed.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!