A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Subglottic Stenosis Position Affects Work of Breathing. | LitMetric

Objectives: Subglottic stenosis (SGS) is the most common type of laryngeal stenosis in neonates. SGS severity is currently graded based on percent area of obstruction (%AO) via the Myer-Cotton grading scale. However, patients with similar %AO can have widely different clinical courses. Computational fluid dynamics (CFD) based on patient-specific imaging can quantify the relationship between airway geometry and flow dynamics. We investigated the effect of %AO and axial position of SGS on work of breathing (WOB) in neonates using magnetic resonance imaging.

Methods: High-resolution ultrashort echo-time MRI of the chest and airway was obtained in three neonatal patients with no suspected airway abnormalities; images were segmented to construct three-dimensional (3D) models of the neonatal airways. These models were then modified with virtual SGSs of varying %AO and axial positioning. CFD simulations of peak inspiratory flow were used to calculate patient-specific WOB in nonstenotic and artificially stenosed airway models.

Results: CFD simulations demonstrated a relationship between stenosis geometry and WOB increase. WOB rapidly increased with %AO greater than about 70%. Changes in axial position could also increase WOB by approximately the same amount as a 10% increase in %AO. Increased WOB was particularly pronounced when the SGS lumen was misaligned with the glottic jet.

Conclusion: The results indicate a strong, predictable relationship between WOB and axial position of the stenotic lumen relative to the glottis, which has not been previously reported. These findings may lead to precision diagnosis and treatment prediction tools in individual patients.

Level Of Evidence: 4 Laryngoscope, 131:E1220-E1226, 2021.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8788627PMC
http://dx.doi.org/10.1002/lary.29169DOI Listing

Publication Analysis

Top Keywords

axial position
12
subglottic stenosis
8
work breathing
8
%ao axial
8
cfd simulations
8
increase wob
8
wob
7
%ao
6
position
4
stenosis position
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!