Accurately measuring body temperature in horses will improve the management of horses suffering from or being at risk of developing postrace exertional heat illness. PTSM has the potential for measuring body temperature accurately, safely, rapidly, and noninvasively. This study was undertaken to investigate the relation between the core body temperature and PTSM temperatures prior to, during, and immediately after exercise. The microchips were implanted into the nuchal ligament, the right splenius, gluteal, and pectoral muscles, and these locations were then compared with the central venous temperature, which is considered to be the "gold standard" for assessing core body temperature. The changes in temperature of each implant in the horses were evaluated in each phase (prior to, during, and immediately postexercise) and combining all phases. There were strong positive correlations ranging from 0.82 to 0.94 ( < 0.001) of all the muscle sites with the central venous temperature when combining all the phases. Additionally, during the whole period, PTSM had narrow limits of agreement (LOA) with central venous temperature, which inferred that PTSM is essentially equivalent in measuring horse body temperature. Overall, the pectoral PTSM provided a valid estimation of the core body temperature.