Iodinated contrast media allergy is rare in patients undergoing sialography.

Asian Pac J Allergy Immunol

Allergy and Clinical Immunology Unit, Department of Medicine, Hadassah-Hebrew University Medical Center, Jerusalem, Israel.

Published: September 2023

Background: Iodinated contrast media allergy is considered as a strong contra-indication for performing sialography. There is little evidence to support this approach.

Objective: To evaluate the rate of iodinated contrast media (ICM) allergy in subjects undergoing sialography and to assess the risk for allergic responses in patients with a previous diagnosis of allergy.

Methods: We retrospectively reviewed sialo-CBCT studies performed from 2014 to 2019. During the study period we implemented a protocol for performing sialo-CBCT in patients with a prior diagnosis of allergy: 1) Clinical data were collected from a questionnaire and medical records. 2) No premedication was administered but, instead, oxygen, epinephrine and a resuscitation cart were accessible. 3) Following the procedure, each patient was observed for one hour and contacted by telephone 24 hrs later.

Results: No allergic responses were documented in the medical records of 1515 subjects following sialo-CBCT studies, including 13 individuals previously diagnosed with ICM allergy. Investigation of the subgroup with prior allergy disclosed that the range of injected volume was between 2 ml to 6.2 ml per patient and that complete secretion of ICM was detected in 7 of 13 patients. In the remainder of subjects, retention rates of 5-50% were observed.

Conclusions: Allergic reactions are exceedingly rare following sialo-CBCT studies regardless of a previous diagnosis of allergy. Pre-medication with corticosteroids and antihistamines is usually not warranted.

Download full-text PDF

Source
http://dx.doi.org/10.12932/AP-190720-0923DOI Listing

Publication Analysis

Top Keywords

iodinated contrast
12
contrast media
12
sialo-cbct studies
12
media allergy
8
undergoing sialography
8
icm allergy
8
allergic responses
8
previous diagnosis
8
diagnosis allergy
8
medical records
8

Similar Publications

Purpose: We investigated the feasibility and advantages of using non-contrast CT calcium score (CTCS) images to assess pericoronary adipose tissue (PCAT) and its association with major adverse cardiovascular events (MACE). PCAT features from coronary computed tomography angiography (CCTA) have been shown to be associated with cardiovascular risk but are potentially confounded by iodine. If PCAT in CTCS images can be similarly analyzed, it would avoid this issue and enable its inclusion in formal risk assessment from readily available, low-cost CTCS images.

View Article and Find Full Text PDF

Evaluation of charge summing correction in CdTe-based photon-counting detectors for breast CT: performance metrics and image quality.

J Med Imaging (Bellingham)

January 2025

U.S. Food and Drug Administration, Office of Science and Engineering Labs, Division of Imaging, Diagnostics, and Software Reliability, Silver Spring, Maryland, United States.

Purpose: We evaluate the impact of charge summing correction on a cadmium telluride (CdTe)-based photon-counting detector in breast computed tomography (CT).

Approach: We employ a custom-built laboratory benchtop system using the X-THOR FX30 0.75-mm CdTe detector (Varex Imaging, Salt Lake City, Utah, United States) with a pixel pitch of 0.

View Article and Find Full Text PDF

Background: The use of iodinated contrast-enhancing agents in computed tomography (CT) improves the visualization of relevant structures for radiotherapy treatment planning (RTP). However, it can lead to dose calculation errors by incorrectly converting a CT number to electron density.

Purpose: This study aimed to propose an algorithm for deriving virtual non-contrast (VNC) electron density from dual-energy CT (DECT) data.

View Article and Find Full Text PDF

Objectives: To conduct a meta-analysis of the diagnostic performance of non-contrast magnetic resonance pulmonary angiography (NC-MRPA) and ventilation-perfusion (V/Q) scintigraphy for the detection of acute pulmonary embolism (PE).

Materials And Methods: Systematic searches of electronic databases were conducted from 2000 to 2024. Primary outcomes were per-patient sensitivity and specificity of NC-MRPA and V/Q scintigraphy.

View Article and Find Full Text PDF

Classical preoperative skin antisepsis is insufficient in completely eliminating bacterial skin colonization for arthroplasty. In contrast, photodynamic therapy (PDT) with red light and methyl-aminolevulinate (MAL), combined with skin antisepsis, led to the absence of bacterial growth in healthy participants, though with local skin erythema, posing an obstacle for orthopedic surgery. Therefore, we explored whether artificial daylight PDT (PDT-DL) was superior to red light.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!