A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Comparison between Recorded and Measured Radiation Doses in Diagnostic Full-field Digital Mammography: A Phantom Study. | LitMetric

Comparison between Recorded and Measured Radiation Doses in Diagnostic Full-field Digital Mammography: A Phantom Study.

J Clin Imaging Sci

Department of Radiologic Sciences, Faculty of Allied Health Sciences, Kuwait University, P.O.Box 31470, Sulaibikhat, Kuwait.

Published: November 2020

AI Article Synopsis

  • The study aimed to assess the discrepancies between directly recorded and measured entrance skin dose (ESD) and average glandular dose (AGD) in full-field digital mammography (FFDM).
  • The researchers evaluated 27 FFDM images using a phantom that simulated different breast thicknesses and compositions, measuring key exposure parameters.
  • Results revealed statistically significant differences between directly recorded and measured doses, but a strong positive correlation suggests that recorded doses can be reliable for quality control in mammography.

Article Abstract

Objectives: There are concerns regarding the difference between directly recorded and measured entrance skin dose (ESD) and average glandular dose (AGD) in full-field digital mammography (FFDM). The objective of the study was to evaluate the effect of different exposure parameters on ESD and AGD recorded directly and measured from an FFDM unit using a phantom.

Material And Methods: The ESD and AGD of 27 FFDM (craniocaudal [CC] projection) images of tissue-equivalent phantoms were acquired using a general electric (GE Senographe Essential) FFDM unit. The phantoms were used to simulate three different breast thicknesses and compositions. Tube potential, tube load, and target/ filter combinations also were recorded directly from the FFDM unit.

Results: The mean differences between the directly recorded and measured ESD and AGD were 0.23 and 0.080, respectively. The 95% confidence intervals for ESD and AGD were 0.1-0.36 and 0.04-0.10, respectively. Results of paired t-test showed statistically significant difference between the directly recorded and measured ESD ( = .001) and AGD ( < .001). A positive and significant correlation was noted between the directly recorded and measured ESD (r = 0.85, < .001) and AGD (r = 0.91, < .001).

Conclusion: This observation confirms that we can use the directly recorded doses obtained from an FFDM for quality control program.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7708958PMC
http://dx.doi.org/10.25259/JCIS_188_2020DOI Listing

Publication Analysis

Top Keywords

recorded measured
20
directly recorded
20
esd agd
16
measured esd
12
full-field digital
8
digital mammography
8
difference directly
8
recorded directly
8
ffdm unit
8
001 agd
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!