Introduction And Aim: Modern knee replacements aim to improve patient function in arthritis affecting different compartments of the knee. This study evaluates the Patient Reported Outcome Measure (PROM) and functional outcome of a modern total knee replacement (Attune, DePuy) in patients with isolated patellofemoral arthritis.

Methods: A total of 50 consecutive patients with isolated unilateral patellofemoral arthritis having had Attune total knee replacements at a single institution between 2010 and 2016 were prospectively studied. Five patients who developed symptoms on the opposite side during the study and two patients lost to follow-up were excluded. One patient needed early revision for loosening, leaving a total of 42 patients to be followed up over a period of 4 years. The Oxford Knee score (OKS) and Knee Injury and Osteoarthritis Outcome Score (KOOS) recorded pre-operatively and at follow-up was compared. A Functional assessment at around 8 months after operation was undertaken.

Results: At average follow-up of 24 months the mean OKS score improved by 15 points and the KOOS score improved by 20 points. Final KOOS sub-score for Pain was 80, Symptom 80, and ADL 82, Sports & Recreation 32 and QOL 60. Functional assessment at mean 8 months showed that a significant number of patients were able to Kneel (50%); Sit cross legged (23%); sit on their heel (23%) and were able do a single leg dip test (86%).

Conclusion: This unique study of a modern design total knee replacement (Attune) in patients with isolated unilateral patellofemoral arthritis shows good PROM scores at 2 years and good functional assessment results at 8 months. The PROM scores are marginally better than the published results with Attune's predecessor, in a similar cohort of patients, but falls short of the published results of patellofemoral replacement implants. Large randomised comparative studies between traditional and the modern implant design is recommended to answer the question if design modification has influenced clinical outcome in patients with patellofemoral arthritis.

Download full-text PDF

Source
http://dx.doi.org/10.1177/2309499020975553DOI Listing

Publication Analysis

Top Keywords

total knee
16
patients isolated
16
knee replacement
12
patellofemoral arthritis
12
functional assessment
12
assessment months
12
patients
10
modern design
8
attune total
8
knee
8

Similar Publications

Blood flow restriction training (BFRT) has been previously studied as an alternative form of resistance training to gain lean mass and improve performance outcomes. However, in all exercise studies of BFRT, the proportion of female participants represents only 17-29% of all research participants. This highlights a strong underrepresentation of females and the need for more knowledge on the impact of BFRT and sex differences.

View Article and Find Full Text PDF

Purpose: This study reports the relationship between posterior cruciate ligament (PCL) retention vs resection and soft tissue laxity and balance throughout flexion using a robotically controlled ligament tensioner.

Methods: 55 robotic-assisted TKAs (Total knee arthroplasty) were retrospectively reviewe. The robotic ligament tensioner collected laxity data both before and after PCL resection.

View Article and Find Full Text PDF

Deep Learning Superresolution for Simultaneous Multislice Parallel Imaging-Accelerated Knee MRI Using Arthroscopy Validation.

Radiology

January 2025

From the Department of Radiology, Division of Musculoskeletal Radiology, NYU Grossman School of Medicine, 660 1st Ave, 3rd Fl, Rm 313, New York, NY 10016 (S.S.W., J.V., R.K., E.H.P., J.F.); Department for Diagnostic and Interventional Radiology, Eberhard Karls University Tübingen, University Hospital Tübingen, Tübingen, Germany (S.S.W.); Department of Radiology, University Hospital Basel, Basel, Switzerland (J.V.); Department of Radiology, Hospital do Coraçao, São Paulo, Brazil (T.C.R.); Academic Surgical Unit, South West London Elective Orthopaedic Centre (SWLEOC), London, United Kingdom (D.D.); Department of Radiology, Balgrist University Hospital, Zurich, Switzerland (B.F.); Department of Radiology, Jeonbuk National University Hospital, Jeonju, Republic of Korea (E.H.P.); Research Institute of Clinical Medicine of Jeonbuk National University, Biomedical Research Institute of Jeonbuk National University Hospital, Jeonju, Republic of Korea (E.H.P.); Medscanlagos Radiology, Cabo Frio, Brazil (A.S.); Centre for Data Analytics, Bond University, Gold Coast, Australia (S.E.S.); Siemens Healthineers AG, Erlangen, Germany (I.B.); and Siemens Medical Solutions USA, Malvern, Pa (G.K.).

Background Deep learning (DL) methods can improve accelerated MRI but require validation against an independent reference standard to ensure robustness and accuracy. Purpose To validate the diagnostic performance of twofold-simultaneous-multislice (SMSx2) twofold-parallel-imaging (PIx2)-accelerated DL superresolution MRI in the knee against conventional SMSx2-PIx2-accelerated MRI using arthroscopy as the reference standard. Materials and Methods Adults with painful knee conditions were prospectively enrolled from December 2021 to October 2022.

View Article and Find Full Text PDF

Introduction: This study aimed to evaluate the effectiveness and safety of intra-articular vancomycin powder in reducing prosthetic joint infections (PJIs) in primary hip and knee arthroplasty through a meta-analysis of randomized controlled trials (RCTs).

Methods: A research in Pubmed, Embase and Cochrane databases was performed to identify randomized clinical trials comparing intra-articular vancomycin use to conventional antibiotic prophylaxis in total hip or knee arthroplasty patients, assessing postoperative infection rates, adverse drug reactions, and venous thrombotic events. Statistical analysis was performed using R (RStudio 2024.

View Article and Find Full Text PDF

Purpose: Robotic-assisted total knee arthroplasty (RA-TKA) has gained popularity for its potential ability to improve surgical precision and patient outcomes, despite concerns about its long learning curve and increased operative times. The aim of this study is to evaluate the learning curve of the ROSA® Knee System, the relationship between each phase of the learning curve and the accuracy of the robotic system in femoral component size and knee alignment prediction.

Methods: A single surgeon retrospective analysis of total operative time (TOT) and total robotic time was conducted.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!