AI Article Synopsis

  • Advances in surface technology have made the use of shorter (8 mm or less) tissue-level implants increasingly common in dental procedures for the posterior maxilla and mandible, with potential advantages.
  • A study analyzed 4,251 such implants placed between 1998 and 2012, tracking their success rates over an average of 127.2 months in function.
  • The findings revealed a cumulative success rate of 99.5%, with high success rates for both regular-neck and wide-neck implants in different locations, supporting the effectiveness of shorter implants in dental restoration.

Article Abstract

Purpose: Advances in surface technology and the understanding of the capabilities of osseointegrating implants have led to the use of shorter implants in a variety of clinical situations. Such implant use offers a number of potential advantages in the posterior maxilla and mandible. The purpose of this retrospective study was to examine the success rates of shorter, tissue-level implants in function for at least 60 months.

Materials And Methods: A retrospective study was conducted of all patients treated between January 1, 1998, and December 31, 2012, who received tissue-level endosseous implants 8 mm or less in length, which were restored with abutments and single crowns. Patient age, sex, location of implants, and diameter of implants were examined. Time in function and stability of peri-implant crestal bone were assessed.

Results: The retrospective analysis identified 4,251 tissue-level implants that were restored with single abutments and crowns. These implants were followed for up to 228 months in function, with a mean time in function of 127.2 months. Implant success was assessed using commonly utilized metrics combined with bone sounding on the midbuccal and midlingual/palatal aspects of the implants. The cumulative success rate was 99.5% for all implants. In the posterior mandible, the success rate for regular-neck implants was 99.3% (n = 680, mean time in function: 136.5 months) and was 99.7% for wideneck implants (n = 2,320, mean time in function: 124.5 months). In the posterior maxilla, the success rate for regular-neck implants was 97.8% (n = 211, mean time in function: 169.1 months), and for wide-neck implants, it was 99.2% (n = 1,040, mean time in function: 127.8 months).

Conclusion: The use of shorter (8 mm or less in length) tissue-level implants in the maxilla and mandible, restored with single abutments and crowns, offers a viable treatment option, assuming specific criteria and protocols are followed. These criteria and protocols are discussed.

Download full-text PDF

Source
http://dx.doi.org/10.11607/jomi.6997DOI Listing

Publication Analysis

Top Keywords

time function
24
implants
16
tissue-level implants
16
success rate
12
function
9
shorter tissue-level
8
implants function
8
228 months
8
posterior maxilla
8
maxilla mandible
8

Similar Publications

We argue that "processes versus objects" is not a useful dichotomy. There is, instead, substantial theoretical utility in viewing "objects" and "processes" as complementary ways of describing persistence through time, and hence the possibility of observation and manipulation. This way of thinking highlights the role of memory as an essential resource for observation, and makes it clear that "memory" and "time" are also mutually inter-defined, complementary concepts.

View Article and Find Full Text PDF

Objective: Loss of function of the phospholipid scramblase (PLS) TMEM16F results in Scott Syndrome, a hereditary bleeding disorder generally attributed to intrinsic platelet dysfunction. The role of TMEM16F in endothelial cells, however, is not well understood. We sought to test the hypothesis that endothelial TMEM16F contributes to hemostasis by measuring bleeding time and venous clotting in endothelial-specific knockout (ECKO) mice.

View Article and Find Full Text PDF

: The purpose of this study was to quantify the impact of smartphone use while sitting on the toilet on the spinal flexion angles and the time effect. : Measurements of the spinal flexion angles in the sagittal plane were made by thirty participants while they sat on the toilet for 10 min, using a smartphone in either one, both, or neither hand. The individual's forehead, cervical, thoracic and lumbar spinal areas were each fitted with five different inertial motion sensors.

View Article and Find Full Text PDF

: External factors can disrupt postural control, but the intricate workings of the postural control system enable an appropriate response. This study seeks to assess how external perturbations affect postural control. : Twenty women participated in study, which consisted four trials involved quiet standing and experiencing induced perturbations by being struck with a boxing bag from the back, right, and left sides, respectively.

View Article and Find Full Text PDF

Acute effect of short-duration static stretching exercises on dynamic balance in U-14 female athletes.

Acta Bioeng Biomech

June 2024

2Department of Individual Sports, High Institute of Sport and Physical Education of Ksar Said, Manouba University, Tunisia.

: The acute effects of static stretching (SS) on dynamic balance, a key fitness component that contributes to injury prevention, has been a subject of significant debate. This study aimed to investigate the acute effect of short-duration SS exercises on dynamic balance following different recovery durations in youth female volleyball players. : Thirteen volunteers U-14 female players were included.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!