Periprosthetic infection after hip replacement is a clinical catastrophic disease, which often leads to the failure of the prosthesis. It needs the combination of systemic antibiotics to cure the infection, which brings huge burden to doctors and patients. There are strict indications for debridement and one-stage revision of the prosthesis, and few cases meet the requirements. The second revision is still the gold standard for the treatment of periprosthetic infection. It is suitable for all infection conditions and has a high success rate. On the second phase of renovation, the antibiotic sustained release system plays a key role, and the carrier of antibiotic sustained-release system is the focus of current research, including classic bone cement and absorbable biomaterials. Bone cement has strong mechanical strength, but the antibiotic release shows a sharp decline trend; the absorbable biomaterials can continuously release antibiotics with high concentration, but the mechanical strength is poor, so it could not use alone. The combination of bone cement and absorbable biomaterials will be an ideal antibiotic carrier. PMMA is the most commonly used antibiotic carrier, but the antibiotic release concentration is decreased sharply after 24 hours. It will be difficult to control the infection and increase the risk of bacterial resistance if it is lower than the minimum inhibitory concentration. The biodegradable materials can release antibiotics completely, with long release time and high concentration, but low mechanical strength. Antibiotic spacer plays an important role in the control of infection. In the future, how to further extend the antibiotic release time of antibiotic sustained-release system, increase the amount of antibiotic release and maintain the mechanical strength of the material will be studied.

Download full-text PDF

Source
http://dx.doi.org/10.12200/j.issn.1003-0034.2020.11.007DOI Listing

Publication Analysis

Top Keywords

mechanical strength
16
antibiotic release
16
periprosthetic infection
12
bone cement
12
absorbable biomaterials
12
antibiotic
11
treatment periprosthetic
8
release
8
carrier antibiotic
8
antibiotic sustained-release
8

Similar Publications

Nanometer-thick ultrathin coatings with superior mechanical strength and desirable lubricating and antifouling performance are critical for the miniaturization of implantable medical devices. However, integrating these properties at the nanoscale remains challenging due to the inherent trade-off between mechanical strength and hydration as well as limitations in coating thickness. In this work, we address these challenges by employing dual-function metal coordination to construct a ∼25 nm thick bilayer structure.

View Article and Find Full Text PDF

The aim of this study was to compare the acute effect of three cluster set (CS) intra-set rest intervals (15 s, 30 s, and 45 s) on mechanical performance measures during a flywheel resistance training session. Twelve amateur male field sport athletes attended three training measurement sessions (separated by 14 days of wash-out), consisting of four sets of nine repetitions (as cluster-blocks: 3 + 3 + 3), using a 0.050 kg·m inertial load.

View Article and Find Full Text PDF

Forward osmosis (FO) technology, known for its minimal energy requirements, excellent resistance to fouling, and significant commercial potential, shows enormous promise in the development of sustainable technologies, especially with regard to seawater desalination and wastewater. In this study, we improved the performance of the FO membrane in terms of its mechanical strength and hydrophilic properties. Generally, the water flux () of polyisophenylbenzamide (PMIA) thin-film composite (TFC)-FO membranes is still inadequate for industrial applications.

View Article and Find Full Text PDF

Enhanced Performance and Durability of Pore-Filling Membranes for Anion Exchange Membrane Water Electrolysis.

Membranes (Basel)

December 2024

Department of Green Chemical Engineering, College of Engineering, Sangmyung University, Cheonan 31066, Republic of Korea.

Four distinct pore-filling anion exchange membranes (PFAEMs) were prepared, and their mechanical properties, ion conductivity, and performance in anion exchange membrane water electrolysis (AEMWE) were evaluated. The fabricated PFAEMs demonstrated exceptional tensile strength, which was approximately 14 times higher than that of the commercial membrane, despite being nearly half as thin. Ion conductivity measurements revealed that acrylamide-based membranes outperformed benzyl-based ones, exhibiting 25% and 41% higher conductivity when using crosslinkers with two and three crosslinking sites, respectively.

View Article and Find Full Text PDF

Dynamical symmetries, time-dependent operators that almost commute with the Hamiltonian, extend the role of ordinary symmetries. Motivated by progress in quantum technologies, we illustrate a practical algebraic approach to computing such time-dependent operators. Explicitly we expand them as a linear combination of time-independent operators with time-dependent coefficients.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!