Radiofrequency catheter ablation is a safe and effective treatment option for atrioventricular nodal reentrant tachycardia (AVNRT). A nonirrigated ablation catheter used in a temperature-controlled mode is traditionally used for AVNRT ablation due to the shallow lesion depth required for successful slow-pathway ablation. In this case, a nonirrigated ablation catheter established inadequate lesions to ablate the slow pathway successfully. The adoption of an irrigated contact-force ablation catheter used in a power-controlled mode was necessary to provide higher power and possibly create a deeper lesion to ablate the slow pathway successfully, thus eliminating AVNRT inducibility in this patient.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7685312PMC
http://dx.doi.org/10.19102/icrm.2020.111103DOI Listing

Publication Analysis

Top Keywords

ablation catheter
12
atrioventricular nodal
8
nodal reentrant
8
reentrant tachycardia
8
nonirrigated ablation
8
ablate slow
8
slow pathway
8
ablation
7
catheter
5
tachycardia ablation
4

Similar Publications

Risk factors for the recurrence of atrial fibrillation after catheter ablation: a meta-analysis.

Egypt Heart J

January 2025

Department of Cardiology, Lianyungang No 1 People's Hospital, No. 6 East Zhenhua Road, Haizhou District, Lianyungang, 222061, Jiangsu, China.

Background: The rate at which atrial fibrillation (AF) patients experience a return of symptoms after catheter ablation is significant, and there are multiple risk factors involved. This research intends to perform a meta-analysis to explore the risk factors connected to the recurrence of AF in patients following catheter ablation.

Methods: The PubMed, Cochrane Library, WOS, Embase, SinoMed, CNKI, Wanfang, and VIP databases were explored for studies from January 1, 2000 to August 10, 2021, and research meeting the established inclusion requirements was chosen.

View Article and Find Full Text PDF

Background: We previously reported the relationship between first-pass pulmonary vein isolation (FPI) and pulmonary vein isolation (PVI) durability in ablation index-guided atrial fibrillation ablation. Obesity is a worsening factor for atrial tachyarrhythmia (AT) recurrence. However, the impact of obesity on FPI has been scarcely reported.

View Article and Find Full Text PDF

Background: It remains unclear whether the newly adopted high-power, short-duration (HP-SD) setting in ablation for atrial fibrillation (AF) impacts periprocedural thrombotic markers or silent stroke (SS) onset.

Objective: The aim of the present study was to investigate the clinical impact of HP-SD setting ablation on changes in periprocedural thrombotic markers and the onset of SS.

Methods: We enrolled 101 AF patients: the HP-SD group (n = 67) using 50 W and the conventional ablation group (n = 34) using 30 to 40 W.

View Article and Find Full Text PDF

Catheter Ablation for Ventricular Tachycardia in Patients With Biopsy-Proven Myocarditis.

JACC Asia

December 2024

Chinese Academy of Medical Sciences, Peking Union Medical College, National Center for Cardiovascular Diseases, Fuwai Hospital, Beijing, China.

Background: Catheter ablation (CA) is increasingly recognized as an effective treatment for ventricular tachycardia (VT) in myocarditis patients, although current evidence is based on less robust data.

Objectives: The purpose of this study was to confirm CA's efficacy in reducing VT recurrence and to identify arrhythmic risk factors in biopsy-proven myocarditis patients.

Methods: In this dual-center, retrospective study, we included 50 patients with biopsy-proven myocarditis and VT.

View Article and Find Full Text PDF