Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 143
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 143
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 209
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 994
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3134
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Versatile high-power pulsed electron-beam accelerators that meet the requirements of pulsed high-power specifications are needed for appropriate applications in medical industry, defense, and other industries. The pulsed electron beam accelerator comprising a Marx generator and Blumlein pulse forming line (PFL) is designed to accelerate the electron beams at the level of 1 MeV when electrostatically discharging. The performance specifications of Marx generators consisting of a 100 kV DC power supply, R-L-C circuit, and high voltage switch are at a maximum 800 kV. At this time, by using the capacitance mismatching principle between the Marx generator and the Blumlein PFL under the law of preserving the amount of charge, it is possible to generate a high voltage in the form of a square pulse up to about 1.1 MV, as much as 1.37 times the charged voltage of the Marx generator. As a result, energy transmission from the Marx generator with a high efficiency of about 85% to the Blumlein PFL is possible. The aim of this study is that the pulsed high-power electron-beam accelerator can be used to change the diode impedance, and the energy of the accelerated electron beam reaches a level of 1 MeV with the square pulse width of about 100 ns at the flat-top in the range of relativistic electron beam generation. Performance tests were securely carried out by installing a dummy load based on CuSO solution varying the diode impedance to deter damage to the circuit by preventing reflected waves from being generated in the load.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1063/5.0025975 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!