A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Development and characterization of thermal helium beam diagnostic with four helium lines for RFX-mod2 experiment. | LitMetric

Development and characterization of thermal helium beam diagnostic with four helium lines for RFX-mod2 experiment.

Rev Sci Instrum

Consorzio RFX (CNR, ENEA, INFN, Università di Padova, Acciaierie Venete SpA), C.so Stati Uniti 4, 35127 Padova, Italy.

Published: November 2020

Thermal Helium Beam (THB) diagnostic is widely used for measuring the electron density and temperature in the boundary region of fusion plasmas, edges, and scrape-off layers. In its standard configuration, it measures three HeI lines (667.8 nm, 706.5 nm, and 728.1 nm) and, by using a collisional-radiative model, evaluates n and T from the ratios of their intensities. At large neutral He density (n ≳ 10 m), radiation re-absorption is not negligible and it has to be taken into account; it can be estimated by measuring the intensity of the fourth HeI line, λ = 501.6 nm. The original THB diagnostic of the RFX-mod experiment has been upgraded, setting up the fourth line intensity acquisition. A Czerny-Turner spectrograph separates the lines, and the old multichannel photomultiplier (PMT) detectors are replaced with the new Multi-Pixel Photon Counter (MPPC). Two 16-channel MPPC array modules allow the observation of 32 signals (4 lines × 8 spatial points). Since the MPPCs are not sensitive to the magnetic field, the whole system can be installed near the experimental device, allowing a large reduction in the optical fibers' length with a gain in the collected signal intensity. This new THB will be installed in the new experiment RFX-mod2, the upgrade of the RFX-mod device. The RFX-mod2 will operate as both reversed field pinch and tokamak, and the goal of the THB is the evaluation of the edge electron density and temperature profiles in the two magnetic configurations, in D or H plasmas. This paper describes the system, the performance of the MPPC compared with the PMTs, the alignment, and the calibration.

Download full-text PDF

Source
http://dx.doi.org/10.1063/5.0023310DOI Listing

Publication Analysis

Top Keywords

thermal helium
8
helium beam
8
thb diagnostic
8
electron density
8
density temperature
8
development characterization
4
characterization thermal
4
beam diagnostic
4
diagnostic helium
4
lines
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!