Study Design: Retrospective cohort study.
Purpose: To identify the clinical significance of different patterns of intraoperative neuromonitoring (IONM) signal alerts.
Overview Of Literature: IONM is a long-established valuable adjunct to complex spine surgeries. IONM for cervical spine surgery is in the form of somatosensory evoked potential (SSEP) and motor evoked potential (MEP). The efficacy of both modalities (individually or in combination) to detect clinically significant neurological compromise is constantly being debated and requires conclusive suggestions.
Methods: Clinical and neuromonitoring data of 207 consecutive adult patients who underwent cervical spine surgeries at multiple surgical centers using bimodal IONM were analyzed. Signal changes were divided into three groups. Group 0 had transient signal changes in either MEPs or SSEPs, group 1 had sustained unimodal changes, and group 2 had sustained changes in both MEPs and SSEPs. The incidences of true neurological deficits in each group were recorded.
Results: A total of 25% (52/207) had IONM signal alerts. Out of these signal drops, 96% (50/52) were considered to be false positives. Groups 0 and 1 had no incidence of neurological deficits, while group 2 had a 29% (2/7) rate of true neurological deficits. The sensitivities of both MEP and SSEP were 100%. SSEP had a specificity of 96.6%, while MEP had a lower specificity at 76.6%. C5 palsy rate was 6%, and there was no correlation with IONM signal alerts (p=0.73).
Conclusions: This study shows that we can better predict its clinical significance by dividing IONM signal drops into three groups. A sustained, bimodal (MEP and SSEP) signal drop had the highest risk of true neurological deficits and warrants a high level of caution. There were no clear risk factors for false-positive alerts but there was a trend toward patients with cervical myelopathy.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8217856 | PMC |
http://dx.doi.org/10.31616/asj.2020.0074 | DOI Listing |
NeuroSci
December 2024
Department of Palliative Medicine, Poznan University of Medical Sciences, 61-701 Poznań, Poland.
Head Neck
December 2024
Department of General Surgery, Vall d'Hebron University Hospital, Barcelona, Spain.
Background: Intraoperative neuromonitoring (IONM) of the recurrent laryngeal nerve (RLN) aims to detect and prevent iatrogenic damage during thyroid surgery. Mechanisms of injury include traction, heat damage, and nerve transection. Continuous IONM (C-IONM) techniques detect impending damage due to traction and heat related when they are still reversible.
View Article and Find Full Text PDFWorld Neurosurg
December 2024
Department of Neurosurgery, West China Hospital, Sichuan University, Chengdu, Sichuan, China. Electronic address:
Diagnostics (Basel)
October 2024
Medical Faculty, University of Belgrade, 11000 Belgrade, Serbia.
Int J Surg
September 2024
Department of Thyroid Surgery, China-Japan Union Hospital of Jilin University, Jilin Provincial Key Laboratory of Translational Medicine in Surgery, Jilin Provincial Engineering; Laboratory of Thyroid Disease Prevention and Treatment Changchun, China.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!