Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: Anemia is a risk factor for adverse outcomes, which can be aggravated by unnecessary phlebotomies. In blood culture testing, up to 30 ml of blood can be withdrawn per sample, even though most manufacturers recommend blood volumes of 10 ml or less. After assessing the filling volume of blood culture bottles at our institution, we investigated whether an educational intervention could optimize filling volume of blood culture bottles without negatively affecting microbiology testing.
Methods: We weighed 10,147 blood cultures before and 11,806 blood cultures after a six-month educational intervention, during which employees were trained regarding correct filling volume via lectures, handouts, emails, and posters placed at strategic places.
Results: Before the educational intervention, only 31% of aerobic and 34% of anaerobic blood cultures were filled correctly with 5-10 ml of blood. The educational intervention increased the percentage of correctly filled bottles to 43% (P < 0.001) for both aerobic and anaerobic samples without negatively affecting results of microbiologic testing. In addition, sample volume was reduced from 11.0 ± 6.5 to 9.4 ± 5.1 ml (P < 0.001) in aerobic bottles and from 10.1 ± 5.6 to 8.8 ± 4.8 ml (P < 0.001) in anaerobic bottles.
Conclusion: Education of medical personnel is a simple and effective way to reduce iatrogenic blood loss and possibly moderate the extent of phlebotomy-induced anemia.