The article shows that noncontact measurement techniques can be an important support to X-ray-based methods when examining the surface condition of modern circulated coins. The forms and degrees of wear of such coins, affecting their utility values, qualifying them as a legal tender in a given country, can be measured and analyzed, among other things, using advanced high-accuracy optical profilometry methods. The authors presented four analyses carried out for reverses and obverses of round coins (1 zloty, 1 franc, 50 bani, 5 pens) characterized by different degrees of surface wear. All of the coins were measured using 3D optical profilometers (Talysurf CLI 2000 and S neox) representing two generations of these types of systems. The obtained results confirm the validity of the applied high-accuracy measurement systems in conjunction with dedicated software in the presented applications. Examples of the analyses carried out can be a significant source of information on the condition of coins in the context of maintaining their functional properties (selection of appropriate wear-resistant alloys and correctness of the production process).

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7729969PMC
http://dx.doi.org/10.3390/ma13235371DOI Listing

Publication Analysis

Top Keywords

high-accuracy optical
8
optical profilometry
8
surface condition
8
condition modern
8
modern circulated
8
circulated coins
8
wear coins
8
analyses carried
8
coins
6
profilometry analysis
4

Similar Publications

Biofilms are resistant microbial cell aggregates that pose risks to health and food industries and produce environmental contamination. Accurate and efficient detection and prevention of biofilms are challenging and demand interdisciplinary approaches. This multidisciplinary research reports the application of a deep learning-based artificial intelligence (AI) model for detecting biofilms produced by Pseudomonas aeruginosa with high accuracy.

View Article and Find Full Text PDF

Scan accuracy of recently introduced wireless intraoral scanners in different fixed partial denture situations.

J Dent

January 2025

Department of Reconstructive Dentistry and Gerodontology, University of Bern, Bern, Switzerland;; Department of Prosthetic Dentistry and Material Science, University Medical Center of the Johannes Gutenberg University Mainz, Mainz, Germany.

Objective: To compare the in vitro scan accuracy (trueness and precision) of recently introduced wireless intraoral scanners (IOSs) to commonly used wired IOSs in different fixed partial denture (FPD) situations.

Methods: Three partially edentulous maxillary models with implants located at different sites (lateral incisors [Model 1]; right canine and first molar [Model 2]; right first premolar and first molar [Model 3]) were digitized with wireless (Primescan 2 [P2] and TRIOS 5 [T5]) and wired (Primescan [P1] and TRIOS 3 [T3]) IOSs (n=14 per IOS-model pair). The models were also digitized with an industrial-grade optical scanner for their reference scans.

View Article and Find Full Text PDF

Eye disease detection has achieved significant advancements thanks to artificial intelligence (AI) techniques. However, the construction of high-accuracy predictive models still faces challenges, and one reason is the deficiency of the optimizer. This paper presents an efficient optimizer named Success History Adaptive Competitive Swarm Optimizer with Linear Population Reduction (L-SHACSO).

View Article and Find Full Text PDF

Objective: To report the development and performance of 2 distinct deep learning models trained exclusively on retinal color fundus photographs to classify Alzheimer disease (AD).

Patients And Methods: Two independent datasets (UK Biobank and our tertiary academic institution) of good-quality retinal photographs derived from patients with AD and controls were used to build 2 deep learning models, between April 1, 2021, and January 30, 2024. ADVAS is a U-Net-based architecture that uses retinal vessel segmentation.

View Article and Find Full Text PDF

Cantilever-Enhanced Fiber-Optic Photoacoustic Spectrophone for Low-Pressure Gas Detection.

Anal Chem

January 2025

School of Optoelectronic Engineering and Instrumentation Science, Dalian University of Technology, Dalian 116024, Liaoning, China.

A cantilever-enhanced fiber-optic photoacoustic (PA) spectrophone is reported for trace gas detection at a low-pressure environment. A cantilever-based fiber-optic Fabry-Perot (F-P) interferometer (FPI) is utilized for simultaneous measurement of air pressure and PA pressure. Since the cantilever resonance frequency follows air pressure linearly, the fundamental frequency intensity modulation (1-IM) technique is applied to scan the frequency response of the solid PA signal from tube wall absorption for tracking the cantilever resonance frequency in real time.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!